430581-004 <strong>POWER</strong>-<strong>MASTER</strong> <strong>500</strong><br />

I) 115 VAC aux il iary power high side<br />

J) 115 VAC Contactor cir cuit, (clo sure be tween<br />

pin I and pin J will en er gize out put).<br />

K) Chas sis ground<br />

L) N/C<br />

M) N/C<br />

N) N/C<br />

14 – Receptacle, 19 Pin : This re cep ta cle al lows<br />

the power source to in ter face with wire feed ers,<br />

and re mote con trols such as a foot pedal. This re -<br />

cep ta cle pro vides aux il iary power, contactor con -<br />

trol for en er giz ing the out put of the power source,<br />

and re mote out put con trol. The pinout is as fol -<br />

lows:<br />

A) Contactor cir cuit (+15 Volts)<br />

B) Contactor cir cuit in, (clo sure be tween pin A<br />

and pin B will en er gize out put).<br />

C) Scaled out put volt age sig nal: Vfb = 10 Arc<br />

Volts/Volt<br />

D) 24 VAC aux il iary power high side<br />

E) 115 VAC aux il iary power high side<br />

F) 24/115 VAC neu tral<br />

G) Chas sis ground<br />

H) Re mote con trol max i mum (top side of<br />

re mote pot.)<br />

J) Re mote con trol in (wiper of re mote pot.,<br />

0 to 10 Volts).<br />

CV Mode: 0 to 10 Volts gives 0 – 44 Volts<br />

CC Mode: 0 to 10 Volts gives 0 – 560 Amps<br />

K) Re mote con trol min i mum (bot tom side of<br />

re mote pot.)<br />

L) Con trol cir cuit com mon<br />

M) Arc Es tab lished = +12 Volts<br />

N) Con trol cir cuit com mon<br />

P) 24 VAC aux il iary power high side<br />

(same as pin D)<br />

R) 24/115 VAC neu tral (same as pin E)<br />

S) N/C<br />

T) N/C<br />

U) Scaled out put cur rent sig nal:<br />

Ifb = 100 Amps/Volt<br />

V) N/C<br />

If a re mote con trol is plugged into both the 14 pin<br />

and 19 pin re cep ta cles the de vice plugged into<br />

the 19 pin re cep ta cle will have con trol over the<br />

out put cur rent or volt age. Ei ther de vice can con -<br />

trol the out put contactor cir cuit.<br />

3-6<br />

15– Du plex: This re cep ta cle can pro vide up to<br />

10 amps of 120 VAC aux il iary power for pow er -<br />

ing wire feed ers, wa ter circulators, etc.<br />

16. Fuse: This fuse pro tects the con trol trans -<br />

former in the power source. If the fuse opens it<br />

should be re placed with a like am per age and<br />

volt age, (20 amps, 600VAC).<br />

17– In put Power Ac cess : This open ing pro -<br />

vides ac cess to the in put ter mi nal block for the in -<br />

put ca ble. See in stal la tion chap ter of this man ual<br />

for de tailed in struc tions.