430581-004 <strong>POWER</strong>-<strong>MASTER</strong> <strong>500</strong><br />

E) Ad just the out put am per age con trol of the<br />

Power-Mas ter <strong>500</strong> un til the am per age dis play<br />

reads ex actly 100.<br />

F) Ver ify the ac tual load amps us ing the ex ter nal<br />

shunt. Load amps should be 100 ± 4 amps.<br />

There is no cal i bra tion ad just ment, if the cal i bra -<br />

tion is off then ei ther the cur rent sen sor or the<br />

con trol board is out of cal i bra tion. At 100 amps of<br />

load cur rent the cur rent sen sor out put should be<br />

0.80 Volts dc.<br />

G) De-en er gize the out put by re mov ing the gun<br />

switch sig nal.<br />

H) Set the ma chine to GMAW mode.<br />

I) Pre set the out put to 24.0 Volts.<br />

J) En er gize the out put us ing the gun switch in put.<br />

The contactor switch on the front panel can not<br />

be used or the volt age read ings will be off.<br />

K) Ver ify the volt age read ing on the front panel<br />

dis play is 24.0 ± 0.2 volts.<br />

L) Ad just the out put volt age con trol on the front<br />

panel of the Power-Mas ter un til the volt age dis -<br />

play reads ex actly 24.0 volts.<br />

M) Ver ify the out put ter mi nal volts di rectly on the<br />

cop per bus bar of the out put ter mi nal us ing the<br />

ex ter nal dig i tal me ter read ing av er age volts.<br />

Volt age should be 24.0 ± 0.5 Volts.<br />

N) If the volt age is out of cal i bra tion, it can be ad -<br />

justed with R68 on the main con trol board.<br />

6-16