The backroom distance is<br />
measured from the back<br />
of the door into the<br />
site, <strong>and</strong> should be at<br />
least 18" more than the<br />
height of the industrial<br />
door.<br />
step one:<br />
A minimum side room of 4" should be available on each side of the<br />
door on the interior wall surface to allow for attachment of the<br />
vertical track assembly. The rough opening should be the same size<br />
as the door.<br />
Headroom is the space needed above the top of the<br />
door for the door, the overhead tracks, <strong>and</strong> the<br />
springs. Measure to check that there are no<br />
obstructions within that space,20" headroom<br />
required at least for industiral door.<br />
vertical tracks<br />
Please keep in mind that the clearance<br />
between the door edge <strong>and</strong> the vertical<br />
track inside edge is 20mm-25mm<br />
(each side,grey part).<br />
On the inside of the opening should be framed with wood<br />
jambs, 2" x 6" if possible. The side<br />
jambs should extend to approximately the same height as<br />
the headroom required.<br />