R<br />

CNS 10 - English<br />

espresso coffee machine - servings count<br />

1.10 PROCEDURE IN CASE OF POWER FAILURE<br />

If there is a power outage, the system will store all data concerning the count of servings delivered.<br />

Since the update of the count takes place at the start of the delivery of the serving, if it is aborted due to a power outage, it is still counted<br />

and recognized by the dosing device. In this case, delivery is not performed and the serving is not counted.<br />

1.11 TECHNICAL DATA<br />

GENERAL DATA<br />

• Power supply voltage 200-230Vac or 100-115Vac<br />

• Operating temperature 10-55°C<br />

• Operating humidity 30-85 % RH without condensation<br />

• Transformer 2 VA - clim.categ. T70/E - 4 KVca<br />

• Input - keys Switch / Pure contact<br />

• Signals for serial transmission RS232 0-5V<br />

CONNECTIONS for “PANEL” model<br />

• Power supply FAST - ON<br />

• Analogue inputs Included for AMPMODU2<br />

• Digital inputs AMPMODU2<br />

• High voltage outputs Included for FAST-ON<br />

• Serial connection AMPMODU2<br />

CONNECTIONS for “COUNTERTOP” model<br />

• Power supply Bi-polar plug<br />

• Digital inputs Cable with activation keys inside the case<br />

• Serial connection 5-way circular connection<br />

1.12 INSTRUCTIONS FOR INSTALLATION AND LIMITATIONS OF USE<br />

WIRING<br />

Wiring of the cards must be laid out in consideration of the need to separate low voltage from high voltage connections.<br />

The length of any cable must be as short as possible to allow correct connection.<br />

If necessary, screened cables must be used.<br />

The unit must also be located far from devices which may create electromagnetic disturbances when in operation, such as pumps, solenoid<br />

valves, remote switches, motors in general, and neon lights.<br />

SURROUNDINGS<br />

The unit must be placed as far as possible from potential heat sources and excessive humidity and from places where, for any reason, condensation<br />

may form.<br />

SOILING<br />

Inside the machine, the card must be suitably protected against soiling.<br />

By definition, “in general, the inside of a unit having a case which sufficiently protects it from dust is considered to be protected against soiling”<br />

(EN 60335-1).