CMA Technical Manual - Love Coffee Machines
CMA Technical Manual - Love Coffee Machines
CMA Technical Manual - Love Coffee Machines
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
R<br />
CNS 10 - English<br />
espresso coffee machine - servings count<br />
1.10 PROCEDURE IN CASE OF POWER FAILURE<br />
If there is a power outage, the system will store all data concerning the count of servings delivered.<br />
Since the update of the count takes place at the start of the delivery of the serving, if it is aborted due to a power outage, it is still counted<br />
and recognized by the dosing device. In this case, delivery is not performed and the serving is not counted.<br />
1.11 TECHNICAL DATA<br />
GENERAL DATA<br />
• Power supply voltage 200-230Vac or 100-115Vac<br />
• Operating temperature 10-55°C<br />
• Operating humidity 30-85 % RH without condensation<br />
• Transformer 2 VA - clim.categ. T70/E - 4 KVca<br />
• Input - keys Switch / Pure contact<br />
• Signals for serial transmission RS232 0-5V<br />
CONNECTIONS for “PANEL” model<br />
• Power supply FAST - ON<br />
• Analogue inputs Included for AMPMODU2<br />
• Digital inputs AMPMODU2<br />
• High voltage outputs Included for FAST-ON<br />
• Serial connection AMPMODU2<br />
CONNECTIONS for “COUNTERTOP” model<br />
• Power supply Bi-polar plug<br />
• Digital inputs Cable with activation keys inside the case<br />
• Serial connection 5-way circular connection<br />
1.12 INSTRUCTIONS FOR INSTALLATION AND LIMITATIONS OF USE<br />
WIRING<br />
Wiring of the cards must be laid out in consideration of the need to separate low voltage from high voltage connections.<br />
The length of any cable must be as short as possible to allow correct connection.<br />
If necessary, screened cables must be used.<br />
The unit must also be located far from devices which may create electromagnetic disturbances when in operation, such as pumps, solenoid<br />
valves, remote switches, motors in general, and neon lights.<br />
SURROUNDINGS<br />
The unit must be placed as far as possible from potential heat sources and excessive humidity and from places where, for any reason, condensation<br />
may form.<br />
SOILING<br />
Inside the machine, the card must be suitably protected against soiling.<br />
By definition, “in general, the inside of a unit having a case which sufficiently protects it from dust is considered to be protected against soiling”<br />
(EN 60335-1).