<strong>Z895</strong> <strong>SERIES</strong>, 1 TO 6 STAGES OPERATING CHARACTERISTICS AT 50 Hz Q = DELIVERY PUMP RATED l/min 0 367 1000 1500 2150 2300 TYPE POWER m 3 /h 0 22 60 90 129 138 H = TOTAL HEAD METRES COLUMN OF WATER kW <strong>Z895</strong> 01 7,5 28,5 27,7 25,3 21,6 12,3 9,8 <strong>Z895</strong> 02/2B 11 38,7 38,3 35,2 27,5 <strong>Z895</strong> 02/2A 15 47,7 46,6 44 36,4 17,8 <strong>Z895</strong> 02 15 57 55,4 50,7 43,2 24,6 19,5 <strong>Z895</strong> 03/2B 18,5 67,2 66,1 60,8 49,4 <strong>Z895</strong> 03/1A 22 81,1 79 73 61,8 34 <strong>Z895</strong> 03 30 86 83,8 77,3 66,4 39 30,4 <strong>Z895</strong> 04/2B 30 96 94,1 86,7 71,8 <strong>Z895</strong> 04/2A 30 104,5 102 94,7 79,7 42,5 <strong>Z895</strong> 04 30 113,8 110,7 101,4 86,5 49,3 39,2 <strong>Z895</strong> 05/3A 37 128 125 116,4 97,5 50,8 <strong>Z895</strong> 05 37 141,9 138 126,4 107,5 60,9 48,7 <strong>Z895</strong> 06/3A 44 158,4 154,8 144,6 122,4 67,1 <strong>Z895</strong> 06 44 172,6 168,1 154,9 132,8 77,7 60,5 DIMENSIONS AND WEIGHTS ELECTRO- PUMP TYPE DIMENSIONS (mm) z895-2p50_a_th ELECTRO- PUMP WEIGHT A (4) C (1) M Tmin (2) kg (3) <strong>Z895</strong> 01-L6C 1237 200 140 1660 73 <strong>Z895</strong> 02/2B-L6C 1459 200 140 1730 89 <strong>Z895</strong> 02/2A-L6C 1514 200 140 1785 96 <strong>Z895</strong> 02-L6C 1514 200 140 1785 96 <strong>Z895</strong> 03/2B-L6C 1741 200 140 1860 112 <strong>Z895</strong> 03/1A-L6C 1801 200 140 1920 118 <strong>Z895</strong> 03-L6C 1931 200 140 2050 131 <strong>Z895</strong> 04/2B-L6C 2083 200 140 2050 140 <strong>Z895</strong> 04/2A-L6C 2083 200 140 2050 140 <strong>Z895</strong> 04-L6C 2083 200 140 2050 140 <strong>Z895</strong> 05/3A-L6C 2365 200 140 2180 162 <strong>Z895</strong> 05-L6C 2365 200 140 2180 162 <strong>Z895</strong> 06/3A-MC8 2532 203,3 192 2195 254 <strong>Z895</strong> 06-MC8 2532 203,3 192 2195 254 z895-2p50_a_td 1) Max electric-pump diameter with 2 motor cables included. In case of 1 motor cable C = 198 mm with L6C motor. C = 201,5 mm with MC8 motor. 2) T min valid only for max flow speed of 4,2 m/s. For higher speeds please contact our sales network. 3) Without cables. 4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg. 14
<strong>Z895</strong> <strong>SERIES</strong>, 1 TO 6 STAGES OPERATING CHARACTERISTICS AT 50 Hz The flow resistance of the ∆Hv non-return valve has not been considered. ∆Hv = 0,0000533*Q 2 Flow resistance = 0,2 / 0,45 / 0,75 m at 60 / 90 / 120 m 3 /h These performances are valid for liquids with density ρ = 1,0 Kg/dm 3 and kinematic viscosity υ = 1 mm 2 /sec. 15