Z855 – Z875 Z895 – Z8125 SERIES
Z855 – Z875 Z895 – Z8125 SERIES
Z855 – Z875 Z895 – Z8125 SERIES
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
TECHNICAL APPENDIX<br />
FW8 <strong>–</strong> FW10 MOTORS<br />
TABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE<br />
MOTOR RATED TEMPERATURE<br />
TYPE POWER °C<br />
kW 25 30 35 40 45 50 55 60 65<br />
FW8 (1) da 30 a 52 1 1 0,93 0,83 0,72 - - - -<br />
FW8 (2) da 30 a 52 1 1 1 1 1 1 0,93 0,83 0,72<br />
FW8 (3) da 55 a 93 1 1 0,92 0,82 0,68 - - - -<br />
FW8 (4) da 55 a 93 1 1 1 1 1 1 0,92 0,82 0,68<br />
FW10 (5) all models 1 0,93 0,83 0,71 - - - - -<br />
FW10 (6) all models 1 1 1 1 1 0,93 0,83 0,71 -<br />
FW8-FW10-derating-50_a_te<br />
(1) Vmin water = 0.2 m/s. Standard windings for water temperature up to 45 °C.<br />
(2) Vmin water = 0.2 m/s. Special windings for water temperature up to 65 °C.<br />
(3) Vmin water = 0.5 m/s. Standard windings for water temperature up to 45 °C.<br />
(4) Vmin water = 0.5 m/s. Special windings for water temperature up to 65 °C.<br />
(5) Vmin water = 0.5 m/s. Standard windings for water temperature up to 40 °C.<br />
(6) Vmin water = 0.5 m/s. Special windings for water temperature up to 60 °C.<br />
EXAMPLE:<br />
An FW845T405, 45 kW motor must work in water at a temperature of 40°C.<br />
Motor power at 40°C = 45 x 0.83 = 37.4 kW<br />
65