TECHNICAL APPENDIX<br />

L6C MOTORS<br />

TABLE OF POWER INCREASE COEFFICIENTS WITH INCREASED WATER TEMPERATURE<br />

MOTOR RATED TEMPERATURE<br />

TYPE POWER °C<br />

kW 35 40 45 50 55 60<br />

L6C all models 1 0,95 0,8 0,75 0,7 0,6<br />

L6c-derating-50_b_te<br />

EXAMPLE:<br />

An L6C, 7.5 kW motor must work in water at a temperature of 45°C.<br />

Motor power at 50°C = 7.5 x 0.8 = 6 kW<br />

MC8 <strong>–</strong> MC10 <strong>–</strong> MC12 MOTORS<br />

TABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE<br />

MOTOR RATED TEMPERATURE<br />

TYPE POWER °C<br />

kW 25 30 35 40 45 50 55 60<br />

MC8 (1) all models 1 0,85 0,74 - - - - -<br />

MC8 (2) all models 1 1 1 1 1 0,85 0,75 0,67<br />

MC10 (1) all models 1 0,85 0,74 - - - - -<br />

MC10 (2) all models 1 1 1 1 1 0,85 0,75 0,67<br />

MC12 (1) all models 1 0,85 0,74 - - - - -<br />

MC12 (2) all models 1 1 1 1 1 0,85 0,75 0,67<br />

(1) Standard windings for water temperature up to 35°C. MC-derating-50_a_te<br />

(2) Special windings for water temperature up to 35 °C to 60 °C.<br />

EXAMPLE:<br />

An MC8-75, 55 kW motor must work in water at a temperature of 35°C.<br />

Motor power at 35°C = 55 x 0.74 = 40.7 kW<br />

F6 <strong>–</strong> F6../316 - F8 MOTORS<br />

TABLE OF POWER INCREASE COEFFICIENTS WITH INCREASED WATER TEMPERATURE<br />

MOTOR RATED TEMPERATURE<br />

TYPE POWER °C<br />

kW 25 30 35 40 45 50 55 60<br />

F6 (1) da 5.5 a 22 1 1 1 1 1 1,14 1,32 1,62<br />

F6, F8 (1) sopra a 22 1 1 1 1 1,14 1,32 1,62 2<br />

(A) Multiply the pump power required by<br />

the increase coefficient from the table.<br />

(B) Select a motor on table whose power is<br />

equal or greater than the calculated value.<br />

(1) Vmin water = 0.91 m/s F6-F8-derating-50_a_te<br />

EXAMPLE:<br />

A <strong>Z855</strong> 06-F6 pump must pump water at a temperature of 50°C.<br />

The power input can be determined from the diagram relating to the pump.<br />

Pa = Power per stage x no. of stages = 4.6 x 6 = 27.6 kW<br />

The pump requires a 30 kW motor.<br />

Power requirement at 50°C = 30 x 1.32 = 39.6 kW<br />