YPE OF PROBLEM<br />
Condition B<br />
(continued)<br />
Condition C<br />
Red lamp on, clear lamp off<br />
Unplug sprayer1<br />
WHAT TO CHECK<br />
f check is OK, go to next check<br />
i. Check microswitch 1306). With no fluid<br />
pressure in the pressure control disconnect<br />
wires TP18 and TP19. Check continuity<br />
across switch terminals with an<br />
ohmmeter. Switch contact should be<br />
closed. Depress actuator bunon. An<br />
audible "click" indicates the contacts<br />
have opened. Ohmmeter should read infinity.<br />
i. Check circuit board (3401 by substituting<br />
with a good board. See page 22.<br />
. Check circuit board (3401 by removing<br />
from box wirhout disconnecting wires;<br />
sea page 22 for removal procedure.<br />
WHAT TO DO<br />
If check is NOT OK refer to this colurn<br />
5. Replace microswitch. See page 19.<br />
3, Replace circuit board. See page 22.<br />
I. Replace circuit board. Sea page 22.<br />
WARNING: Removing the circuit board<br />
while still wired over-rides the optical<br />
detector which could cause the sprayer<br />
. to over-pressurize, if the microswitch<br />
does not function properly. Tum the<br />
sprayer on ONLY long enough to check<br />
lamp condition, then shut off immediately.<br />
WARNING: To reduce the risk of electric<br />
shock, handle board by edges only1<br />
Do not allow any metal objects to come<br />
in contacl with the boardl<br />
Plug in and turn on sprayer. Clear lamp<br />
should be on now - removing the circuit<br />
board over-rides the optical detector.<br />
Turn off and unplug sprayer.<br />
!. Check bourdon tube flag and detector<br />
position. Reinstall circuit board ( see page<br />
22. Turn pressure setting to maximum;<br />
flag should extend less than half way into<br />
optical detector slot from the bonom.<br />
2. Calibrate pressure control to sea if that<br />
corrects problem. See page 24.<br />
If not, replace bare pressure control box<br />
13011'. See page 23.<br />
DETECTOR<br />
CIRCUIT-<br />
BOARD<br />
VIEW OF OPTICAL DETECTOR AND FLAG<br />
'When replacing the bare pressire control box 13011. remow the ON/OFFswitch, bridge,<br />
circuit board and elecbical hardware and reinstall in the new bare box.<br />
Tmubleshooting continued on next page.<br />
307-671 11