YPE OF PROBLEM<br />

Condition B<br />

(continued)<br />

Condition C<br />

Red lamp on, clear lamp off<br />

Unplug sprayer1<br />

WHAT TO CHECK<br />

f check is OK, go to next check<br />

i. Check microswitch 1306). With no fluid<br />

pressure in the pressure control disconnect<br />

wires TP18 and TP19. Check continuity<br />

across switch terminals with an<br />

ohmmeter. Switch contact should be<br />

closed. Depress actuator bunon. An<br />

audible "click" indicates the contacts<br />

have opened. Ohmmeter should read infinity.<br />

i. Check circuit board (3401 by substituting<br />

with a good board. See page 22.<br />

. Check circuit board (3401 by removing<br />

from box wirhout disconnecting wires;<br />

sea page 22 for removal procedure.<br />

WHAT TO DO<br />

If check is NOT OK refer to this colurn<br />

5. Replace microswitch. See page 19.<br />

3, Replace circuit board. See page 22.<br />

I. Replace circuit board. Sea page 22.<br />

WARNING: Removing the circuit board<br />

while still wired over-rides the optical<br />

detector which could cause the sprayer<br />

. to over-pressurize, if the microswitch<br />

does not function properly. Tum the<br />

sprayer on ONLY long enough to check<br />

lamp condition, then shut off immediately.<br />

WARNING: To reduce the risk of electric<br />

shock, handle board by edges only1<br />

Do not allow any metal objects to come<br />

in contacl with the boardl<br />

Plug in and turn on sprayer. Clear lamp<br />

should be on now - removing the circuit<br />

board over-rides the optical detector.<br />

Turn off and unplug sprayer.<br />

!. Check bourdon tube flag and detector<br />

position. Reinstall circuit board ( see page<br />

22. Turn pressure setting to maximum;<br />

flag should extend less than half way into<br />

optical detector slot from the bonom.<br />

2. Calibrate pressure control to sea if that<br />

corrects problem. See page 24.<br />

If not, replace bare pressure control box<br />

13011'. See page 23.<br />

DETECTOR<br />

CIRCUIT-<br />

BOARD<br />

VIEW OF OPTICAL DETECTOR AND FLAG<br />

'When replacing the bare pressire control box 13011. remow the ON/OFFswitch, bridge,<br />

circuit board and elecbical hardware and reinstall in the new bare box.<br />

Tmubleshooting continued on next page.<br />