Troubleshooting 49/65<br />

7.2 Failure in 10 MBit/s Half Duplex Mode and Workaround<br />

Affected Hardware<br />

Hardware with the communication controller netX <strong>50</strong>, netX 100 or<br />

netX <strong>50</strong>0; netX/Internal PHYs.<br />

When can this Failure occur?<br />

When using standard Ethernet communication with 10 MBit/s half duplex<br />

mode, the PHY gets stuck in case of network collisions. Then no further<br />

network communication is possible. Only device power cycling allows<br />

Ethernet communication again.<br />

This problem can only occur with Ethernet TCP/UDP IP, EtherNet/IP or<br />

Modbus TCP protocols when using hubs at 10 MBit/s. The issue described<br />

above is not applicable for protocols which use 100 MBit/s or full duplex<br />

mode.<br />

Solution / Workaround:<br />

Do not use 10 MBit/s-only hubs. Use either switches or 10/100 MBit/s Dual<br />

Speed hubs, to make sure the netX Ethernet ports are connected with 100<br />

MBit/s or in full duplex mode.<br />

This erratum is fixed with all components of the ‘Y’ charge (9 digit charge<br />

number shows ‘Y’ at position 5 (nnnnYnnnn).<br />

Reference<br />

“Summary of 10BT problemon EthernetPHY”,<br />

RenesasElectronics Europe, April 27, 2010<br />

<strong>netLINK</strong> <strong>NL</strong> <strong>50</strong>-<strong>MPI</strong> Ethernet | Installation, Operation and Hardware Description<br />

DOC080604UM05EN | Revision 5 | English | 2011-09 | Released | Public © Hilscher, 2008-2011