• Adding coagulant aids or flocculants such as cationic polymers to increase the removal<br />

of the fine iron oxide particles;<br />

• Using pumps for removing the iron oxide in the scale pits, sedimentation tanks, and<br />

collection tank to eliminate draining of the wastewater onto the ground; and<br />

• -Increasing the frequency of iron oxide removal in the scale pits within the rolling mill.<br />

2. Flying Shear Cooling Water Elimination - Eliminate the once-through cooling of the pipe prior<br />

to the flying shears or capture and return it to the rolling mill wastewater treatment system.<br />

3. Hydraulic Fluid Leak Reduction - Reduce the quantity of hydraulic oil in the cooling water with<br />

improved maintenance (both preventive and corrective programs) of the equipment to prevent<br />

or correct hydraulic fluid leaks.<br />

4. Reheating Furnace Cooling Water EV