1.7 Technical Data<br />

TRIVAC BCS<br />

Nominal pumping speed 1) m 3 · h -1 (cfm)<br />

Pumping speed 1)<br />

m 3 · h -1 (cfm)<br />

Ult. partial pr. without gas ballast 1) mbar<br />

Torr<br />

Ultimate total pr. without gas ballast 1) mbar<br />

Torr<br />

Ultimate total pr. with gas ballast 1) mbar<br />

Torr<br />

Water vapour tolerance 1) mbar (Torr)<br />

Oil filling, min./max.<br />

l<br />

Connections<br />

DN<br />

Motor protection<br />

IP<br />

Weight *<br />

kg (lbs)<br />

Motor power *<br />

W<br />

Noise level * to DIN 45 635<br />

without/with gas ballast<br />

dB (A)<br />

D 40 BCS<br />

two-stage<br />

D 65 BCS<br />

two-stage<br />

46 (27.1) 75 (44.2)<br />

40 (23.6) 65 (38.3)<br />

10 -4 10 -4<br />

0.75 ·10 -4 0.75 ·10 -4<br />

< 2 · 10 -3 < 2 · 10 -3<br />

< 1.5 · 10 -3 < 1.5 · 10 -3<br />

< 5 · 10 -3 < 5 · 10 -3<br />

< 3.8 · 10 -3 < 3.8 · 10 -3<br />

40 (30) 40 (30)<br />

1.7/2.6 2.0/3.3<br />

40 KF 40 KF<br />

54 54<br />

68 (149.9) 80 (176.4)<br />

1500 2200<br />

57/59 57/59<br />

TRIVAC BCS with three-phase motor<br />

230/400 V, 50 Hz / 250/440 V, 60 Hz Cat. No. 113 88 Cat. No. 113 98<br />

TRIVAC BCS-PFPE D 40 BCS-PFPE D 65 BCS-PFPE<br />

two-stage<br />

two-stage<br />

Nominal pumping speed 1)<br />

Pumping speed 1)<br />

m 3 · h -1 (cfm)<br />

m 3 · h -1 (cfm)<br />

Ultimate partial pr. without gas ballast 1)<br />

Ultimate total pressure w. gas ballast 1)<br />

Lubricant filling<br />

min./max.<br />

upon delivery<br />

Connections<br />

Motor protection<br />

Weight *<br />

Motor power *<br />

Noise level * to DIN 45 635,<br />

without/with gas ballast<br />

mbar<br />

Torr<br />

mbar<br />

Torr<br />

l<br />

l<br />

DN<br />

IP<br />

kg (lbs)<br />

W<br />

dB (A)<br />

46 (27.1) 75 (44.2)<br />

40 (23.6) 65 (38.3)<br />

< 8 · 10 -4 < 8 · 10 -4<br />

< 6 · 10 -4 < 6 · 10 -4<br />

< 5 · 10 -3 < 5 · 10 -3<br />

< 3.8 · 10 -3 < 3.8 · 10 -3<br />

1.5/2.5 2.0/3.5<br />

0.6 0.75<br />

40 KF 40 KF<br />

54 54<br />

71 (156.6) 83 (183)<br />

2200 2200<br />

57/59 57/59<br />

TRIVAC BCS-PFPE with three-phase motor<br />

230/400 V, 50 Hz / 250/440 V, 60 Hz<br />

200/400 V, 50 Hz / 200/400 V, 60 Hz<br />

Cat. No. 113 89 Cat. No. 113 99<br />

Cat. No. 154 52 Cat. No. 154 54<br />

1) To DIN 28 400 and subsequent numbers<br />

* Length, weight, motor power and noise level for the models with three-phase motor.<br />