Usable cross-section and quantity of cables<br />

A lot of space for a lot of cables<br />

The mono and the duo ducts are<br />

extremely spacious and offer ample<br />

room for line installation. The<br />

trunking depth of 53 mm and the<br />

compact design of the EGS devices<br />

enable the lines to be installed<br />

either above, below or behind the<br />

switches and sockets. The following<br />

tables list the recommended<br />

maximum filling volumes (50%<br />

filling) of the empty and filled Rapid<br />

45 trunking for standard cable<br />

types.<br />

Calculation formula for cable assignment<br />

in the trunking<br />

To calculate the recommended cable<br />

assignment for trunking, you<br />

require the following data:<br />

• Trunking cross-section: D · H<br />

(in mm)<br />

• Realistic space requirements<br />

of the cables: (2r) 2<br />

• Max. filling factor (recommended):<br />

0.5<br />

This data allows calculation of the<br />

usable cross-section for cable assignment,<br />

as follows:<br />

Usable cross-section for cable assignment<br />

= (trunking cross-section<br />

/ (2r) 2 ) · 0.5<br />

Planning aid, device installation trunking, size 45<br />

06 <strong>LFS</strong>_Katalog_2010_Neuer_Stand / en / 25/02/2010 (LLExport_00995)<br />

GEK-K 53100<br />

GEK-A 53100<br />

Without device<br />

installation<br />

With device<br />

installation<br />

Trunking cross-section 4,080 mm² 2,596 mm²<br />

NYM<br />

3 x 1.5 mm<br />

d = 10.5 mm<br />

NYM<br />

5 x 1.5 mm<br />

d = 12 mm<br />

Telecommunications<br />

cable<br />

J-Y(St.)Y 2 x 0.6<br />

d = 5 mm<br />

23 15<br />

18 11<br />

104 66<br />

Filling factor:<br />

0.5 = the capacity<br />

reserve is 50%.<br />

GEK-K 53160<br />

GEK-A 53160<br />

NYM<br />

3 x 1.5 mm<br />

d = 10.5 mm<br />

NYM<br />

5 x 1.5 mm<br />

d = 12 mm<br />

Without device installation<br />

Telecommunications<br />

cable<br />

J-Y(St.)Y 2 x 0.6<br />

d = 5 mm<br />

With device<br />

installation<br />

6,480 mm² 3,696 mm²<br />

36 20<br />

28 15<br />

156 96<br />

Filling factor:<br />

0.5 = the capacity<br />

reserve is 50%.<br />