HP ProCurve Networking Datasheets - Moonblink
HP ProCurve Networking Datasheets - Moonblink
HP ProCurve Networking Datasheets - Moonblink
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>HP</strong> <strong>ProCurve</strong> Wireless Access Point 10ag<br />
Specifications<br />
<strong>HP</strong> <strong>ProCurve</strong> Wireless Access Point 10ag NA (J9140A)<br />
<strong>HP</strong> <strong>ProCurve</strong> Wireless Access Point 10ag WW (J9141A)<br />
Ports<br />
Physical characteristics<br />
Dimensions (D x W x H)<br />
Weight<br />
1 RJ-45 auto-sensing 10/100 port (IEEE 802.3 Type 10Base-T,<br />
IEEE 802.3u Type 100Base-TX)<br />
Duplex: half or full<br />
4.06 x 7.01 x 1.34 in. (10.3 x 17.8 x 3.4 cm)<br />
0.62 lb. (0.28 kg)<br />
1 RJ-45 auto-sensing 10/100 port (IEEE 802.3 Type 10Base-T, IEEE<br />
802.3u Type 100Base-TX)<br />
Duplex: half or full<br />
4.06 x 7.01 x 1.34 in. (10.3 x 17.8 x 3.4 cm)<br />
0.62 lb. (0.28 kg)<br />
Memory and processor<br />
Processor MIPS 4000 @ 220 MHz, 16 MB SDRAM, 2 MB flash ROM MIPS 4000 @ 220 MHz, 16 MB SDRAM, 2 MB flash ROM<br />
Environment<br />
Operating temperature<br />
Operating relative humidity<br />
Non-operating/Storage temperature<br />
Non-operating/Storage relative humidity<br />
Altitude<br />
Electrical characteristics<br />
Description<br />
Maximum heat dissipation<br />
Current<br />
Maximum power rating<br />
Frequency band and Operating<br />
FCC (US and Canada)<br />
32ºF to 104ºF (0ºC to 40ºC)<br />
5% to 95% @ 104ºF (40ºC), non-condensing<br />
–40ºF to 158ºF (–40ºC to 70ºC)<br />
5% to 95% @ 158ºF (70ºC), non-condensing<br />
Up to 10,000 ft. (3 km)<br />
Voltage: 48 VDC (PoE); 12 VDC (power adapter); 110/220 V 50/60 Hz<br />
25/33 BTU/hr (26.38/34.82 kJ/hr)<br />
0.6 A/0.2 A<br />
7 W<br />
2.412–2.462 GHz (11 channels)<br />
5.150–5.250 GHz (4 channels)<br />
5.725–5.825 GHz (5 channels)<br />
32ºF to 104ºF (0ºC to 40ºC); PoE mode<br />
5% to 95% @ 104ºF (40ºC), non-condensing<br />
–40ºF to 158ºF (–40ºC to 70ºC)<br />
5% to 95% @ 158ºF (70ºC), non-condensing<br />
Up to 10,000 ft. (3 km)<br />
Voltage: 48 VDC (PoE); 12 VDC (power adapter); 110/220 V 50/60 Hz<br />
25/33 BTU/hr (26.38/34.82 kJ/hr)<br />
0.6 A/0.2 A<br />
7 W<br />
Taiwan<br />
2.412–2.462 GHz (11 channels)<br />
5.725–5.825 GHz (5 channels)<br />
European Union<br />
Japan<br />
China<br />
Singapore<br />
Korea<br />
2.412–2.472 GHz (13 channels)<br />
5.150–5.250 GHz (4 channels)<br />
2.412–2.484 GHz (14 channels)<br />
5.150–5.350 GHz (8 channels)<br />
2.412–2.472 GHz (13 channels)<br />
5.725–5.825 GHz (5 channels)<br />
2.412–2.472 GHz (13 channels)<br />
5.150–5.350 GHz (8 channels)<br />
5.725–5.825 GHz (5 channels)<br />
2.412–2.472 GHz (13 channels)<br />
5.150–5.350 GHz (8 channels)<br />
5.470–5.725 GHz (7 channels)<br />
5.725–5.825 GHz (4 channels)<br />
Australia<br />
Radio<br />
FCC Part 15.247; FCC Part 15.407 (US); RSS-210 (Canada);<br />
EN 300 328; ARIB STD-T66; ARIB STD-T71; ARIB STD-33;<br />
RSS-Gen (Canada); EN 301 893 V1.2.3 (Europe)<br />
2.412–2.472 GHz (13 channels)<br />
5.725–5.825 GHz (5 channels)<br />
Safety UL 60950-1; CAN/CSA 22.2 No. 60950-1 IEC 60950-1; EN 60950-1<br />
Emissions FCC Part 15.107; EN 60601-1-2; EN 301 489-1; EN 301 489-17;<br />
FCC Part 15.109; ICES-003 (Canada)<br />
RF Exposure FCC Bulletin OET-65C; IEEE C95.1; RSS-102 EN 50385<br />
FCC Part 15.247; FCC Part 15.407 (US); RSS-210 (Canada);<br />
EN 300 328; ARIB STD-T66; ARIB STD-T71; ARIB STD-33;<br />
RSS-Gen (Canada); EN 301 893 V1.2.3 (Europe)<br />
FCC Part 15.107; EN 60601-1-2; EN 301 489-1; EN 301 489-17;<br />
FCC Part 15.109; ICES-003 (Canada)<br />
Management <strong>HP</strong> <strong>ProCurve</strong> Manager; Web browser <strong>HP</strong> <strong>ProCurve</strong> Manager; Web browser<br />
Notes<br />
Antennas: integral 2.4 GHz 1.8 dBi diversity antennas; 5 GHz 1.8 dBi<br />
diversity antennas<br />
199