Surface feedback<br />

ASU (operation & maintenance by AL): no issue / Built and operated by Air Liquid<br />

Oxy-burners (AL equipment): no issue – start-up on air-combustion up to 30% load, then<br />

oxy-combustion up to 100%. Stable flames.<br />

Oxy-boiler: very smooth operation, oxy-boiler efficiency at least as high as air-boiler<br />

efficiency. No operating issues. Only problem is boiler degradation due to retrofit from under<br />

to over atmospheric pressure.<br />

Flue Gas Recycle: no issue<br />

Cooling tower : no issue<br />

<strong>Lacq</strong> compressor (reciprocating – 3 stages – wet): we had corrosion issues (mainly 3rd<br />

stage) because of nitric acid formation (dissolution of NO2 in water) due to liquid water<br />

carry-over from scrubbers towards the suction chambers. Scrubbers have been upgraded<br />

and compressor operating conditions adapted. The compressor now runs corrosion free.<br />

Dryers(AL molecular sieves): no issue<br />

Pipe from <strong>Lacq</strong> to Rousse (existing – 27km – carbon steel): no issue<br />

Rousse compressor (reciprocating – one stage – dry): no issue<br />

<strong>IPIECA</strong> Workshop Washington DC, USA 20-21 September 2011. <strong>Dominique</strong> <strong>Copin</strong>