QuantaMAX and Standard Filters<br />

for Fluorescence<br />

design of these <strong>filters</strong> also offers the benefit of an increased ability<br />

to attenuate off axis rays such as those found in instruments using<br />

high system speeds or less than optimally collimated light sources<br />

such as light emitting diodes (LED).<br />

Dichroic mirror substrates utilize UV-grade fused silica to take<br />

advantage of the high level of internal uniformity of this glass,<br />

therefore offering excellent transmitted wave-front distortion<br />

(TWD) and transmission values across the operational range of the<br />

substrate.<br />

of contrast is to minimize non-specific light from reaching the<br />

detector. A typical research grade CCD camera has a quantum<br />

efficiency range from ~350-1100 nm. By designing each filter<br />

to offer near band blocking of ≥ OD 6, and extended blocking to<br />

> OD 5, QMAX <strong>filters</strong> offer outstanding noise suppression though<br />

the entire integrated range of the detector.<br />

Figure 3<br />

Optical Density curve of XF407 set<br />

QuantaMAX - Stock <strong>filters</strong> are available for immediate shipment;<br />

25 mm round emission and excitation and 25.7 x 36 mm dichroic.<br />

Additional sizes are available upon request.<br />

Spectral Performance:<br />

Single fluorophore QuantaMAX <strong>interference</strong> <strong>filters</strong> and filter sets<br />

provide 90% minimum transmission across the pass-band, and<br />

routinely exhibit values greater. When using a sensitive detection<br />

technique such as fluorescence, a key to achieving high levels<br />

Optical Density<br />

Wavelength<br />

vivid and basic - Standard <strong>interference</strong> Filters<br />

Vivid and Basic - Standard <strong>interference</strong> <strong>filters</strong> and filter sets may<br />

be comprised of our speedy small volume manufacturing process<br />

or large component inventory. They are not immediately available<br />

off-the-shelf but are available to ship in 5 business days (expedited<br />

deliveries are available upon request), and are customized to your<br />

physical and spectral requirements. Applications involving novel<br />

fluorophores or multiplexing systems where customized bandwidths<br />

are a must are examples of where a product from the standard filter<br />

program can be offered to optimize the system performance. The<br />

strategy of small lot builds and the incorporation of off-the-shelf<br />

components provides for <strong>filters</strong> of nearly any characteristic to be<br />

produced in a fast and economical fashion.<br />

Vivid Filters:<br />

The Vivid product line utilizes a proprietary method of monitoring<br />

and controlling the coating process. This technology yields <strong>filters</strong><br />

with exceptionally high signal to noise and steep transistion slopes,<br />

making them suitable for demanding applications. Vivid <strong>filters</strong> offer<br />

precise and accurate location of cut on and cut off edges with<br />

tolerances of +/- 0.01 – +/- 0.05 % of the 50% wavelength edge.<br />

Basic Filters:<br />

The Basic <strong>filters</strong> offer excellent performance at a reasonable<br />

cost. These <strong>filters</strong> and filter sets are optimized for the specified<br />

application and utilize multi-cavity, Fabry-Perot designs to achieve<br />

a rectangular bandpass shape with very steep edges and deep<br />

blocking up to OD6 outside the passband.<br />

Flexible and efficient manufacturing:<br />

Vivid and Basic - Standard <strong>interference</strong> <strong>filters</strong> are assembled from<br />

our component inventory library of thousands of filter and blockers,<br />

along with our speedy turn-around manufacturing capabilities, to<br />

provide solutions for unique applications. Some examples of these<br />

applications are narrow band Quantum dot specific <strong>filters</strong>, ratio<br />

imaging <strong>filters</strong>, UV activated photo-switchable proteins, along with<br />

many of the less commonly used fluorophores such as Indocyanine<br />

Green. These products will meet the requirements for both industry<br />

and research where a stock catalog part may not provide the ideal<br />

characteristics for the application and without the added cost of a<br />

custom manufactured filter and associated lead times.<br />

Specifications:<br />

Vivid and Basic - Standard <strong>filters</strong> are designed to functional<br />

specifications of the best <strong>optical</strong> performance at a reasonable<br />

price and delivery. Typically, standard band-pass excitation <strong>filters</strong><br />

reach minimum 75 % transmission. Standard <strong>filters</strong> that do not<br />

require extended blocking can exhibit up to 80-90 % transmission.<br />

Standard long and short-pass <strong>filters</strong> will average > 90 % transmission<br />

over the specified operating spectral range. All imaging <strong>filters</strong> are<br />

polished to ≥ 15 arc seconds parallelism and anti-reflection coating<br />

applied to minimize deviation and reflection. Dichroic mirrors are<br />

built on the same high quality substrate material as those in the<br />

stock program for imaging qualities.<br />

70<br />

For current product listings, specifications, and pricing:<br />

www.omega<strong>filters</strong>.com • sales@omega<strong>filters</strong>.com<br />

1.866.488.1064 (toll free within USA only) • +1.802.254.2690 (outside USA)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!