28.04.2014 Views

Drawings for Sewer and Water - City of London

Drawings for Sewer and Water - City of London

Drawings for Sewer and Water - City of London

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

STANDARD CONTRACT DOCUMENTS<br />

FOR MUNICIPAL CONSTRUCTION<br />

PROJECTS<br />

SUPPLEMENTAL STANDARDS FOR SEWER<br />

AND WATER<br />

2014 EDITION<br />

SUPERSEDED/DELETED<br />

(REMOVE)<br />

AMENDED/NEW/CURRENT<br />

(INSERT)<br />

OPSD<br />

CITY OF<br />

LONDON<br />

DATED<br />

TITLE OF<br />

DRAWING<br />

CITY OF<br />

LONDON<br />

DATED<br />

TITLE OF<br />

DRAWING<br />

W-CS-12 2000-02-29<br />

St<strong>and</strong>ard Mechanical<br />

Joint Offset Installation<br />

Using Tiebolt Couplings<br />

W-CS-12 2012-01-26<br />

St<strong>and</strong>ard Mechanical Joint<br />

Offset Installation Using<br />

Tiebolt Couplings<br />

W-CS-12<br />

Sht 2<br />

2000-02-29<br />

Grip Ring Restrainer<br />

Assembly<br />

W-CS-12<br />

Sht 3<br />

2006-11-06 Typical Restraint Details<br />

W-CS-22 1991-01-30<br />

St<strong>and</strong>ard Installation <strong>of</strong><br />

40mm & 50mm <strong>Water</strong><br />

Service<br />

W-CS-22 2007-10-16<br />

St<strong>and</strong>ard Installation <strong>of</strong><br />

40mm & 50mm <strong>Water</strong><br />

Service<br />

W-CS-24 2000-02-29<br />

Cathodic Protection<br />

Assemblies <strong>for</strong> 20mm to<br />

50mm <strong>Water</strong> Service<br />

W-CS-25 1999-01-30<br />

Cathotic Protection <strong>for</strong><br />

100mm <strong>and</strong> Larger <strong>Water</strong><br />

Services<br />

W-CS-30<br />

Sht 1<br />

1991-01-30<br />

Typical Installation <strong>for</strong><br />

20mm, 40mm, <strong>and</strong> 50mm<br />

Disc Type <strong>Water</strong><br />

Meter(Sheet 1)<br />

W-CS-30<br />

Sht 2<br />

1999-01-30<br />

Typical Turbine <strong>Water</strong> Meter<br />

Installation <strong>for</strong> 75mm to<br />

200mm<br />

W-CS-31 1999-01-30<br />

Schematic Layout <strong>of</strong><br />

100mm <strong>and</strong> Larger<br />

Service<br />

W-CS-31<br />

Sht 1<br />

2004-11-01<br />

Schematic Layout <strong>of</strong> 100mm<br />

<strong>and</strong> Larger Service<br />

W-CS-43<br />

Sheet 1<br />

W-CS-43<br />

Sheet 2<br />

W-CS-43<br />

Sheet 3<br />

2004-11-01<br />

2004-11-01<br />

2004-11-01<br />

Typical Thrust Blocks <strong>for</strong><br />

<strong>Water</strong>mains (sht 1)<br />

Typical Vertical Thrust<br />

Blocks For <strong>Water</strong>mains<br />

(sht 2)<br />

Typical Thrust Blocks <strong>for</strong><br />

<strong>Water</strong>mains (sht 3)<br />

W-CS-45 1999-01-30<br />

W-CS-51 1999-01-30<br />

St<strong>and</strong>ard Location <strong>for</strong> <strong>Water</strong><br />

Valves at Intersections With<br />

9.0m <strong>and</strong> 10.5m Curb Radii<br />

St<strong>and</strong>ard <strong>City</strong> <strong>of</strong> <strong>London</strong><br />

737mm Frame <strong>and</strong> Cover<br />

W-CS-60 1999-01-30 Sterilizing Mains<br />

<strong>City</strong> <strong>of</strong> <strong>London</strong> |2014 Edition<br />

SW-59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!