Drawings for Sewer and Water - City of London
Drawings for Sewer and Water - City of London
Drawings for Sewer and Water - City of London
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
\st<strong>and</strong>ardsW.dgn 2012-03-28 2:23:25 PM<br />
c\^ó<br />
TIEBOL T JOINT<br />
E o<br />
@m<br />
ROD ASSEMBLY<br />
FOR D.I. AND P.V.C. PIPE<br />
SPECIAL LONG<br />
RESTRAINER ASSEMBLY<br />
FOR P.V.C. PIPE<br />
TIE ROD ASSEMBLY USING CLAMP<br />
FOR D.I. PIPE<br />
UNIFLANGE SERIES<br />
I3OO-C RESTRAINER<br />
RES T RAINER<br />
LEGEND:<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
H<br />
EXISTING WATERMAIN<br />
ÂPPROVED CLAMP<br />
REOUIRED M.J. BEND<br />
FILLER PIECE<br />
APPROVED TIEROD (THREADED COR-TEN STEEL)<br />
M.J. SLEEVE<br />
APPROVED TIEBOLT JOINT RESTRAINER<br />
APPROVED TIENUT<br />
MINIMUM CLEARANCE AS<br />
PERCOFLDESIGN<br />
SPECTFtCATT0NS 7.4.7.2.<br />
& M.O.E. PROCEDURE F-6-I<br />
SEWER OR OTHER<br />
OBSTRUCTION<br />
NOTES:<br />
I. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE SHOWN.<br />
2. THIS DETAIL TO BE USED FOR OFFSETS ON IOO, I5O &<br />
2OO DIA. MAINS. OFFSETS ON LARGER MAINS REOUIRE<br />
INDIVIDUAL APPROVAL.<br />
3. IF OFFSET IS INSTALLED IN HORIZONTAL OR INVERTED<br />
POSIÏION, MINIMUM COVER TO BE DECIDED BY ENGINEER.<br />
4. ONE PAIR 0F 20mm DlA. RODS FOR 100, 150 & 200 DtA. P|PE.<br />
5. COVER TIEBOLT ASSEMBLY WITH DENSO PASTE MASTIC<br />
AND TAPE ALL TO MANUFACTURER'S SPECIFICATIONS.<br />
6. ALL RESTRAINERS MUST BE APPROVED BY THE CITY OF<br />
LONDON.<br />
CITY OF LONDON STANDARD DRAWING<br />
STANDARD MECHANICAL JOINT OFFSET INSTALI-ATION USING TIEBOLT COUPLINGS