Additional factors must be considered when deciding whether to advise evacuation or<br />

sheltering in place in response to a radiological terrorist incident. Earlier<br />

recommendations by the EPA for evacuation were written for a nuclear power plant<br />

accident in which the release of radioactive material would occur hours after the initial<br />

accident, allowing the population to be evacuated in a plume-free environment. However,<br />

a terrorist attack is more likely to release a plume within minutes rather than hours of the<br />

initiation of the event. Therefore, sheltering is likely to be more protective in response to<br />

a radiological terrorist event. Sheltering should be performed whenever it is more<br />

protective than evacuation.<br />

Sheltering in place for protection from radioactive fallout is also an effective<br />

countermeasure with little negative impact for short periods of time (hours) <strong>and</strong> may be<br />

done in a fallout shelter, an underground area, or in the middle of a large building. Any<br />

roofed structure would be of some benefit <strong>and</strong> would protect people from alpha <strong>and</strong> beta<br />

radiation, because the structure would keep radioactive particles from falling on the skin<br />

<strong>and</strong> further reduce the chance of inhalation. The degree of protection from gamma<br />

radiation increases with the type of material used in constructing the shelter, from wood,<br />

to masonry, to metal, metal being the most effective. Glass is not very effective in<br />

preventing the penetration of gamma radiation, <strong>and</strong> windows should be avoided because<br />

of the risk of lacerations from broken glass due to pressure changes or other<br />

consequences of the accident. Sheltering generally reduce exposures to external <strong>and</strong><br />

internal contamination by 5 to 10 times. Sheltering is almost always justified if it will<br />

prevent exposures of 0.050 Sv (5 rem). At exposures