Vehicle maintenance<br />
Water Draining Procedure from Sedimenter<br />
5. Before filling in fresh oil in the<br />
engine, clean the drain plug and<br />
apply sealant on threads.<br />
6. Refit the drain plug using a new<br />
sealing washer. Tighten drain plug<br />
to 5 mkg. torque.<br />
7. Fill, recommended quantity of<br />
fresh engine oil in the crank case<br />
and secure the oil filler cap in its<br />
place.<br />
8. Start the engine and run for a few<br />
minutes. The engine oil pressure<br />
indicator lamp should go ‘off’ after<br />
starting the engine.<br />
9. Check for engine oil leakages.<br />
10.Stop the engine and recheck<br />
engine oil level after a few<br />
minutes. If necessary add oil to<br />
bring the level to the upper mark<br />
on the dipstick.<br />
NOTICE<br />
Use of reclaimed oil is not<br />
recommended.<br />
Water Sedimenter<br />
Water draining Procedure from<br />
Sedimenter :<br />
The water sedimenter is part of the<br />
Fuel filtration system, fitted to the<br />
chassis frame, near fuel tank below<br />
the vehicle. It is used in the fuel<br />
supplying system in order to reduce<br />
the water content in the fuel provided<br />
to the DICOR system.<br />
A water sensor is fitted to the water<br />
sedimenter in order to indicate to the<br />
driver that the sedimenter has to be<br />
drained. Whenever water in fuel<br />
sedimenter Indicator glows in<br />
instument cluster, the water need to<br />
be drained from the sedimenter.<br />
Water drain operation to be done on<br />
both filter and sedimenter.<br />
Procedure :<br />
1. Stop the engine, and wait until<br />
pressure stabilizes.<br />
2. Unclip one of the hydraulic<br />
connections (either inlet or outlet)<br />
and the electric connector of the<br />
water sensor. 3 Place a container<br />
underneath the water sedimenter.<br />
3. Place a container underneath the<br />
water sedimenter.<br />
4. Unscrew the water sensor about<br />
2 - 3 turns<br />