Malfunctions<br />

Z.1.<br />

Malfunctions with error messages<br />

Led blinks + warning symbol)<br />

If the <strong>controller</strong> detects a malfunction, the red light fl ashes and the warning symbol<br />

also appears in the display. If the error is no longer present, the warning symbol<br />

changes to an info symbol and the red light no longer fl ashes.<br />

To obtain more detailed information on the error, press the key under the warning<br />

or info symbol.<br />

Danger<br />

Do not try to deal with this yourself.<br />

Consult a specialist in the event of an error!<br />

Possible error messages:<br />

Sensor defective<br />

Collector alarm<br />

Restart<br />

Time & Date<br />

System protection<br />

Collector protection<br />

Recooling<br />

Frost protection<br />

Frequent on / off<br />

No fl ow<br />

Pressure: Failure<br />

SD card error<br />

Notes for the specialist:<br />

Means that either the sensor, the sensor input at the <strong>controller</strong> or the connecting cable is/<br />

was defective.<br />

(Resistance table see „B.2. - Temperature resistance table for Pt1000 sensors“ on page 5)<br />

Means that the collector has fallen/fell below the temperature set under menu „5.6. - Collector<br />

alarm“ on page 26<br />

Means that the <strong>controller</strong> was restarted, for example due to a power failure. Check the<br />

date&time!<br />

This message appears automatically after a mains failure because the time&date have to<br />

be checked, and reset if necessary.<br />

Collector temperature overshot the set temperature, the solar pump was switched OFF to<br />

prevent damage due to excessive heat.<br />

Collector temperature overshot the set temperature, the solar pump was switched ON to<br />

prevent damage to the collector due to excessive heat.<br />

Excessive heat was radiated via the collector to protect the system.<br />

The solar pump was switched on to prevent damage to the collector.<br />

When the solar pump is switched off and on more than 5 times in 5 minutes, this message<br />

is displayed.<br />

This message is displayed when the solar pump is running and for 5 minutes the dT >=50°C<br />

This message is displayed when pressure monitoring is activated and the limits Pmin or<br />

Pmax are exceeded.<br />

This message is displayed when an SD card is detected, but cannot be read or written on.<br />