When using the VQ Probe with G5 1.6 with more than one protocol,<br />

Skinny must be configured ahead of H323. If it is not,<br />

HTIPSigserver cannot be started.<br />

DTMF may not be sent correctly when the DTMF Type is set to In<br />

Band for highly compressed codecs.<br />

<strong>OneSight</strong> Voice Engine and <strong>OneSight</strong> Voice Quality – Advanced<br />

Monitors - There is a limit to the number of monitors that can be<br />

configured on a Data Collector. To avoid overloading a Data Collector, it<br />

is recommended that no more than thirty-five OSVE scripts with less than<br />

ten steps be configured on a Data Collector. An indication that a Data<br />

Collector is overloaded can be found by checking for stale samples from<br />

the Support and Diagnostics page in <strong>OneSight</strong>.<br />

<strong>OneSight</strong> Voice Quality – Advanced Monitors Location Tab - When<br />

setting up a <strong>OneSight</strong> Voice Quality Advanced monitor, you must select<br />

only the default location on the locations tab during monitor creation.<br />

Multiple locations are not supported.<br />

Metric Performance Report for Voice Quality Basic monitors – The<br />

Metric Performance Report for Voice Quality Basic monitors cannot be<br />

modified when drilled down to a one hour time frame. The Modify button<br />

is displayed; however, it disappears when you click on it.<br />

VQ Probe - Restarting the HT Server – If you manually restart the HT<br />

Server, only the A side scripts are restarted for the VQ Probe. Restart the<br />

<strong>OneSight</strong> Data Collector to start the B side scripts.<br />

VQ Probe Command Not Completed in Time Error – This error<br />

occurs due to a known FX/TDM issue that causes the HT Server process<br />

to stop. You can avoid this problem either by connecting all of the D-<br />

channels or by stopping the D-channels that are not in use.<br />

VQ Probe - UNIStim – When using the UNIStim protocol, the VQ Probe<br />

always uses the G.711 U-Law protocol to make calls regardless of the<br />

codec selected in the VQ Probe Configuration dialog box.<br />

Data Collectors for WebLogic 9.2 – New Data Collector installations<br />

for WebLogic 9.2 require an update for the OSDC.properties file to<br />

prevent discovery from failing. Add the following line to the<br />

[Agents.JMX] section:<br />

Agents.JMX.MAPPING.weblogic92 = weblogic9.2<br />

Modified Default Alert Message Templates After Upgrade – If you<br />

have modified a default alert message template, changes may not be<br />

6<br />

6 <strong>OneSight</strong> <strong>Release</strong> <strong>Notes</strong>