28.07.2014 Views

CATALOGUE 201ME JANUARY 2004

CATALOGUE 201ME JANUARY 2004

CATALOGUE 201ME JANUARY 2004

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>CATALOGUE</strong> <strong>201ME</strong> — Page 25<br />

BUILT-IN CHECK VALVE SERIES Refrigerants 22, 134a, 401A, 402A, 404A, 407C, 502, 507<br />

SPECIFICATIONS for REVERSE REFRIGERATION FLOW, Liquid Line Capacity - kW**<br />

VALVE<br />

TYPE<br />

C(M)B9,<br />

C(M)E9<br />

C(M)B10,<br />

C(M)E10<br />

C(M)B14,<br />

C(M)E14<br />

C(M)B19,<br />

C(M)E19<br />

+<br />

CONNECTIONS<br />

Inches<br />

R-22<br />

0.21 bar<br />

5 20<br />

3/8,<br />

1/2 ODF, 3/8 SAE<br />

23.<br />

2 1. 8<br />

1/2<br />

SAE, 1/2, 5/8 ODF<br />

28.<br />

5 6. 7<br />

5/8<br />

ODF<br />

45.<br />

4 2. 9<br />

5/8,<br />

7/8 ODF<br />

32.<br />

7 1. 0<br />

R-134a<br />

0.14 bar<br />

R-401A<br />

0.14 bar<br />

R-402A<br />

0.21 bar<br />

R-404A<br />

0.21 bar<br />

R-407C<br />

0.21 bar<br />

R-502<br />

0.21 bar<br />

R-507<br />

0.21 bar<br />

E VAPORATOR °C<br />

-2<br />

5 -20<br />

5 -20<br />

5 -20<br />

5 -20<br />

5 -20<br />

5 -20<br />

17.<br />

16.<br />

2 19.<br />

3 17.<br />

6 — 13.<br />

7 — 13.<br />

7 21.<br />

5 19.<br />

7 — 13.<br />

7 — 13. 4<br />

21.<br />

19.<br />

7 23.<br />

2 21.<br />

5 — 16.<br />

9 — 16.<br />

9 26.<br />

0 23.<br />

9 — 16.<br />

5 — 16. 5<br />

35.<br />

32.<br />

7 38.<br />

7 35.<br />

9 — 27.<br />

1 — 27.<br />

4 42.<br />

2 38.<br />

7 — 26.<br />

7 — 26. 7<br />

21.<br />

19.<br />

7 23.<br />

2 21.<br />

5 -—<br />

19.<br />

0 -—<br />

17.<br />

9 28.<br />

8 26.<br />

4 -—<br />

19.<br />

3 -—<br />

17. 9<br />

- 5 0<br />

2 9<br />

2 8<br />

4 9<br />

3 8<br />

** Valve sizing should be based on expected reverse liquid flow condensing capabilities of the evaporator(s) being defrosted.<br />

+ Due to flow restrictions, C(M)E19 models capacity does not surpass C(M)E14 model until pressure drop exceeds 0.70 bar.<br />

See Page 21 for Forward Refrigerant Flow.<br />

Liquid capacities shown in the above table are based on 38°C liquid temperature entering the valves.<br />

INDUSTRIAL SOLENOID VALVES<br />

for Air, Water, Steam and Light Oil<br />

DISC TYPE - APPLICATION<br />

These valves are suitable for most types of<br />

industrial applications. Ideal for water, light<br />

oils, air lines to chucking devices, steam<br />

lines, etc. Use the disc type valves for high temperature and steam<br />

applications up to 1.72 bar. Use the teflon diaphragm type valve for<br />

high temperature and steam applications over 0.34 bar (107 °C) but<br />

do not exceed 0.68 bar (115°C).<br />

The W3P1 is the ideal size for use on air chucking devices.<br />

Generally, a very tight seat is required for this type of application.<br />

This can be achieved by using a neoprene seat in the W3P1 in place<br />

of the standard teflon. To order specify RW3P1.<br />

TYPE<br />

W3P1<br />

W6P1<br />

W14P2<br />

W19P2<br />

W25P2<br />

CAPACITIES<br />

STANDARD PORT MOPD<br />

Ar i – m<br />

CONNECTIONS SIZE AC<br />

3 Steam – kg/hr<br />

/ hr<br />

Water<br />

– m /hr<br />

0.34<br />

bar ∆ P<br />

inches<br />

mm bar 0.34 bar 0.69 bar 0.34 bar 1.38 bar Inlet Pressure<br />

∆ P ∆ P ∆ P ∆ P 0.34<br />

bar 0.69<br />

bar<br />

WATTS<br />

1/4<br />

NPT Female<br />

2.77<br />

4.08<br />

5.78<br />

0.11<br />

0.27<br />

3.40<br />

3.90<br />

3/8<br />

NPT Female<br />

4.76<br />

12.<br />

3 18.<br />

4 0.50<br />

1.02<br />

10.<br />

4 11. 8<br />

1/2<br />

NPT Female<br />

11.<br />

1 10.3 41.<br />

1 67.<br />

1 1.34<br />

2.88<br />

34.<br />

9 39. 9<br />

3/4<br />

NPT Female<br />

15.<br />

1<br />

69.<br />

7 104<br />

2.00<br />

4.34<br />

60.<br />

3 68. 5<br />

1 NPT Female<br />

19.<br />

8<br />

126<br />

194<br />

3.29<br />

7.38<br />

101<br />

135<br />

STANDARD<br />

COIL<br />

RATINGS<br />

COIL<br />

10<br />

MKC-1<br />

15<br />

MKC-2<br />

DIAPHRAGM TYPE - APPLICATION<br />

These valves are suitable for most types<br />

of industrial applications. Ideal for water,<br />

light oils, air lines to chucking devices,<br />

steam lines, etc. Use the disc type valves<br />

for high temperature and steam applications up to 1.72 bar. Use<br />

the teflon diaphragm type valve for high temperature and steam<br />

applications over 0.34 bar (107°C) but do not exceed 0.68 bar<br />

(115°C).<br />

Diaphragm type industrial solenoid valves are tight seating in applications<br />

of normal differential pressure. For applications where differential<br />

pressures in the closed position are below 0.34 bar, it is recommended<br />

that a Buna-N diaphragm be used in place of the standard<br />

teflon diaphragm. To order specify BR184P1.<br />

Q><br />

TYPE<br />

R183P1<br />

BR183P1<br />

R184P1<br />

BR184P1<br />

R246P1<br />

BR246P1<br />

STANDARD<br />

CONNECTIONS<br />

inches<br />

PORT<br />

SIZE<br />

mm<br />

MOPD<br />

AC<br />

bar<br />

0.34 bar<br />

∆P<br />

CAPACITIES<br />

Ar i – m 3<br />

3<br />

/ hr<br />

Water<br />

– m /hr<br />

0.69 bar<br />

∆P<br />

0.34 bar<br />

∆P<br />

1.38 bar<br />

∆P<br />

Steam – kg/hr<br />

0.34<br />

bar ∆P<br />

Inlet Pressure<br />

0.34<br />

bar 0.69<br />

bar<br />

WATTS<br />

3/8<br />

NPT Female 14.<br />

3 10.<br />

3 55.<br />

2 80.<br />

5 1.84<br />

3.66<br />

47.<br />

6 69. 0<br />

1/2<br />

NPT Female 14.<br />

3 10.<br />

3 62.<br />

9 91.<br />

8 2.09<br />

4.16<br />

54.<br />

0 78. 5<br />

3/4<br />

NPT Female 19.<br />

1 10.<br />

3 88.<br />

9 130<br />

2.93<br />

5.86<br />

76.<br />

2 111<br />

Q> “R” type valves have Teflon diaphragm – 115˚C Max. Fluid Temperature; “BR” type valves have Buna-N diaphragm –107˚C Max. Fluid Temperature.<br />

STANDARD<br />

COIL<br />

RATINGS<br />

COIL<br />

10<br />

MKC-1<br />

Use a SPORLAN strainer ahead of every industrial solenoid valve.<br />

For complete information refer to Bulletin 30-10.