28.07.2014 Views

CATALOGUE 201ME JANUARY 2004

CATALOGUE 201ME JANUARY 2004

CATALOGUE 201ME JANUARY 2004

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Page 44 — <strong>CATALOGUE</strong> <strong>201ME</strong><br />

HEAD PRESSURE CONTROL VALVE<br />

Capacities – kW<br />

ADJUSTABLE VALVE TYPES and ORD TYPE<br />

Capacities based on 38°C liquid, 5°C evaporator temperature and 8°C change in condensing temperature to stroke the valve.<br />

VALVE TYPE<br />

ORI-6<br />

65/225 psig<br />

4.5/15.5 bar<br />

ORI-10<br />

65/225 psig<br />

4.5/15.5 bar<br />

PRESSURE<br />

DROP - bar<br />

REFRIGERANT<br />

22<br />

134a<br />

401A<br />

402A<br />

404A<br />

407C<br />

502<br />

507<br />

0.10<br />

34<br />

25<br />

27<br />

26<br />

25<br />

32<br />

23<br />

25<br />

0.20<br />

50<br />

37<br />

39<br />

37<br />

36<br />

47<br />

33<br />

36<br />

0.30<br />

62<br />

46<br />

49<br />

46<br />

45<br />

59<br />

41<br />

45<br />

0.40<br />

72<br />

53<br />

57<br />

54<br />

52<br />

68<br />

48<br />

53<br />

0.10<br />

90<br />

63<br />

67<br />

70<br />

68<br />

87<br />

60<br />

69<br />

0.20<br />

125<br />

87<br />

92<br />

97<br />

94<br />

120<br />

83<br />

95<br />

0.30<br />

151<br />

105<br />

112<br />

117<br />

113<br />

145<br />

101<br />

115<br />

0.40<br />

172<br />

120<br />

128<br />

134<br />

130<br />

166<br />

115<br />

131<br />

Capacities based on 32°C liquid at the receiver, 5°C evaporator temperature and includes both the discharge gas bypassed as well as the liquid<br />

capacity flowing through the adjustable ORI valve.<br />

VALVE TYPE<br />

ORD-4-20<br />

@ -18 ° C ambient<br />

PRESSURE<br />

DROP<br />

- bar<br />

REFRIGERANT<br />

22<br />

134a<br />

401A<br />

402A<br />

and 404A<br />

407C<br />

502<br />

507<br />

1.72<br />

97<br />

76<br />

80<br />

72<br />

83<br />

69<br />

72<br />

2.07<br />

105<br />

81<br />

86<br />

77<br />

89<br />

74<br />

77<br />

PILOT OPERATED TYPES<br />

Capacities based on 38°C condensing and 5°C evaporator temperature.<br />

VALVE TYPE<br />

ORIT-15<br />

65/225 psig<br />

4.5/15.5 bar<br />

ORIT-20<br />

65/225 psig<br />

4.5/15.5 bar<br />

PRESSURE<br />

DROP<br />

- bar<br />

REFRIGERANT<br />

22<br />

and 401A<br />

134a<br />

402A<br />

and 404A<br />

407C<br />

502 and 507<br />

..<br />

0.28*<br />

124<br />

115<br />

81<br />

113<br />

79<br />

0.40<br />

193<br />

180<br />

126<br />

177<br />

124<br />

0.50<br />

256<br />

238<br />

167<br />

234<br />

164<br />

..<br />

0.28*<br />

316<br />

294<br />

205<br />

288<br />

203<br />

0.40<br />

551<br />

512<br />

357<br />

501<br />

354<br />

0.50<br />

617<br />

574<br />

400<br />

562<br />

397<br />

* The ORIT valve requires a 0.28 bar pressure drop across the valve port to open.<br />

Capacities are based on 38°C condensing, -20°C minimum ambient, 5°C evaporator, 5.6°C superheat and 28°C added to isentropic discharge<br />

temperatures.<br />

VALVE TYPE<br />

CROT-12<br />

65/225 psig<br />

4.5/15.5 bar<br />

CROT-15<br />

65/225 psig<br />

4.5/15.5 bar<br />

PRESSURE<br />

DROP<br />

- bar<br />

REFRIGERANT<br />

22<br />

134a<br />

401A<br />

402A<br />

and 404A<br />

407C<br />

502<br />

507<br />

0.70<br />

185<br />

146<br />

155<br />

135<br />

157<br />

130<br />

134<br />

1.00<br />

220<br />

173<br />

183<br />

160<br />

187<br />

154<br />

160<br />

1.40<br />

259<br />

203<br />

215<br />

189<br />

220<br />

182<br />

188<br />

0.70<br />

330<br />

259<br />

275<br />

238<br />

279<br />

230<br />

238<br />

1.00<br />

393<br />

311<br />

329<br />

287<br />

335<br />

276<br />

286<br />

1.40<br />

464<br />

366<br />

388<br />

338<br />

395<br />

326<br />

337<br />

INSTALLATION — The ORI, OROA, and<br />

LAC valves are installed in the condenser<br />

liquid drain line and the ORD and CROT are<br />

installed in a hot gas bypass line around the<br />

condenser. When installing these valves, the<br />

internal parts should be protected by wrapping<br />

the valves with wet cloths.<br />

Connections –<br />

(Standard connections are in bold type)<br />

OROA-5 – 5/8, 7/8 ODF Solder<br />

LAC-4 – 3/8, 1/2 ODF Solder<br />

LAC-5 – 1/2, 5/8, 7/8, 1-1/8 ODF Solder<br />

LAC-10 –<br />

Discharge Connection:<br />

1-3/8 ODF Solder<br />

Receiver and Condenser Connections:<br />

7/8 or 1-1/8 ODF Solder<br />

ORI-6 – 5/8, 7/8, 1-1/8 ODF Solder<br />

ORI-10 – 1-1/8, 1-3/8 ODF Solder<br />

ORD-4 – 5/8 ODF Solder<br />

ORIT-15 – 1-3/8 ODF Solder<br />

ORIT-20 – 1-5/8 ODF Solder<br />

CROT-12 – 1-1/8 ODF Solder<br />

CROT-15 – 1-3/8 ODF Solder<br />

For complete information refer to Bulletin 90-30, 90-30-2 and F90-30-4.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!