<strong>CATALOGUE</strong> <strong>201ME</strong> — Page 31<br />

LIQUID LINE RATINGS and SELECTION RECOMMENDATIONS<br />

TYPE<br />

C-032<br />

C-032-CAP<br />

C-032-S<br />

C-032-F<br />

C-032-FM<br />

Refrigerant<br />

22<br />

60 PPM<br />

WZ<br />

RATINGS<br />

AT ARI STANDARD CONDITIONS<br />

WATER CAPACITY – GRAMS<br />

Refrigerant<br />

134a<br />

50 PPM<br />

Refrigerant<br />

404A/507<br />

50 PPM<br />

Refrigerant<br />

407C<br />

50 PPM<br />

Refrigerant<br />

410A<br />

50 PPM<br />

W?<br />

REFRIGERANT FLOW CAPACITY<br />

kW at 0.07 bar ∆P<br />

SELECTION RECOMMENDATIONS<br />

REFRIGERATION<br />

Commercial & Low<br />

Temperature Equipment<br />

25°<br />

C 50°<br />

C 25°<br />

C 50°<br />

C 25°<br />

C 50°<br />

C 25°<br />

C 50°<br />

C 25°<br />

C 50°<br />

C 22<br />

134a<br />

404A/507<br />

407C<br />

410A<br />

134a<br />

22<br />

58<br />

3.<br />

1 2.<br />

5 3.<br />

4 2.<br />

4 3.<br />

6 2.<br />

9 2.<br />

6 0.<br />

9 1.<br />

4 1. 0<br />

SEALED TYPE<br />

5.28<br />

4.57<br />

3.52<br />

4.57<br />

4.92<br />

C-033<br />

12.<br />

3 11.<br />

3 8.09<br />

11.<br />

3 12. 0<br />

C-033-S<br />

13.<br />

4 12.<br />

3 9.14<br />

12.<br />

3 13. 0<br />

C-052<br />

C-052-S<br />

C-052-F<br />

C-052-FM<br />

97<br />

7.<br />

3 6.<br />

0 7.<br />

9 5.<br />

7 8.<br />

5 6.<br />

9 6.<br />

2 2.<br />

0 3.<br />

2 2. 4<br />

7.39<br />

6.68<br />

4.92<br />

6.68<br />

7.03<br />

C-0525-S<br />

12.<br />

0 10.<br />

9 8.09<br />

10.<br />

9 11. 6<br />

C-053<br />

14.<br />

4 13.<br />

4 9.50<br />

13.<br />

4 14. 1<br />

C-053-S<br />

16.<br />

5 15.<br />

1 10.<br />

9 15.<br />

1 15. 8<br />

C-082<br />

C-082-S<br />

7.39<br />

6.68<br />

4.92<br />

6.68<br />

7.03<br />

C-0825-S<br />

13.<br />

0 11.<br />

6 8.44<br />

11.<br />

6 12. 3<br />

C-083<br />

135<br />

12.<br />

0 9.<br />

8 13.<br />

1 9.<br />

4 14.<br />

0 11.<br />

4 10.<br />

1 3.<br />

3 5.<br />

2 3. 9 15.<br />

8 14.<br />

8 10.<br />

6 14.<br />

8 15. 5<br />

C-083-S<br />

18.<br />

3 16.<br />

5 12.<br />

0 16.<br />

5 17. 6<br />

C-084<br />

30.<br />

6 27.<br />

8 20.<br />

7 28.<br />

1 29. 9<br />

C-084-S<br />

33.<br />

8 30.<br />

9 22.<br />

5 30.<br />

9 33. 1<br />

C-162<br />

C-162-S<br />

7.39<br />

6.68<br />

4.92<br />

6.68<br />

7.03<br />

C-1625-S<br />

13.<br />

0 11.<br />

6 8.44<br />

11.<br />

6 12. 3<br />

C-163<br />

15.<br />

8 14.<br />

8 10.<br />

6 14.<br />

8 15. 5<br />

C-163-S<br />

213<br />

17.<br />

3 14.<br />

9 19.<br />

8 14.<br />

3 21.<br />

2 17.<br />

3 15.<br />

4 5.<br />

0 7.<br />

9 6. 0 18.<br />

3 16.<br />

5 12.<br />

0 16.<br />

5 17. 6<br />

C-164<br />

35.<br />

5 32.<br />

7 23.<br />

9 32.<br />

7 34. 2<br />

C-164-S<br />

38.<br />

7 35.<br />

5 25.<br />

7 35.<br />

5 37. 6<br />

C-165<br />

48.<br />

5 44.<br />

3 32.<br />

4 44.<br />

7 47. 1<br />

C-165-S<br />

55.<br />

9 51.<br />

0 37.<br />

3 51.<br />

3 54. 5<br />

C-303<br />

16.2<br />

14.<br />

8 10.<br />

6 14.<br />

8 15. 5<br />

C-303-S<br />

18.<br />

6 16.<br />

5 12.<br />

0 16.<br />

5 17. 6<br />

C-304<br />

35.<br />

5 32.<br />

7 23.<br />

9 32.<br />

7 34. 5<br />

C-304-S<br />

342<br />

34.<br />

8 28.<br />

4 37.<br />

8 27.<br />

3 40.<br />

5 32.<br />

9 29.<br />

3 9.<br />

5 15.<br />

1 11. 4 38.<br />

7 35.<br />

5 25.<br />

7 35.<br />

5 37. 6<br />

C-305<br />

52.<br />

4 47.<br />

8 34.<br />

8 48.<br />

2 51. 0<br />

C-305-S<br />

59.<br />

4 54.<br />

5 39.<br />

7 54.<br />

5 57. 7<br />

C-307-S<br />

76.<br />

0 69.<br />

6 50.<br />

6 70.<br />

0 73. 9<br />

C-414<br />

WX SURFACE<br />

FILTERING AREA<br />

cm 2<br />

THE PERFECT<br />

FILTER-DRIER Refrigerants 22, 134a, 404A, 407C, 410A, 507<br />

40.5<br />

36.<br />

9 26.<br />

7 36.<br />

9 39. 0<br />

C-414-S<br />

43.<br />

6 40.<br />

1 29.<br />

2 40.<br />

1 42. 6<br />

C-415<br />

55.<br />

6 51.<br />

0 37.<br />

3 51.<br />

4 54. 2<br />

C-415-S<br />

432<br />

46.<br />

8 35.<br />

7 50.<br />

9 36.<br />

7 54.<br />

4 44.<br />

3 39.<br />

4 12.<br />

7 20.<br />

4 15. 3<br />

61.<br />

5 56.<br />

6 41.<br />

5 57.<br />

0 60. 1<br />

C-417-S<br />

77.<br />

7 71.<br />

4 52.<br />

0 71.<br />

8 25. 6<br />

C-419-S<br />

85.<br />

5 78.<br />

4 57.<br />

3 78.<br />

8 83. 4<br />

C-607-S<br />

102<br />

93.<br />

6 68.<br />

6 94.<br />

3 100<br />

684<br />

69.<br />

6 56.<br />

7 75.<br />

6 54.<br />

5 80.<br />

9 65.<br />

8 58.<br />

6 18.<br />

9 30.<br />

2 22. 7<br />

C-609-S<br />

117<br />

107<br />

78.<br />

4 108<br />

114<br />

404A, 502<br />

& 507<br />

kW<br />

AIR CONDITIONING<br />

Field Replacement<br />

or Field Built Up<br />

Systems<br />

134a<br />

22, 407C<br />

& 410A<br />

0.88<br />

0.88<br />

0.88<br />

1.76<br />

1.76<br />

1.17<br />

1.17<br />

1.17<br />

1.76<br />

thru<br />

5.28<br />

3.52<br />

thru<br />

7.03<br />

10.6<br />

thru<br />

17.6<br />

17.6<br />

thru<br />

35.2<br />

1.76<br />

thru<br />

5.28<br />

5.28<br />

thru<br />

10.6<br />

10.6<br />

thru<br />

17.6<br />

17.6<br />

thru<br />

42.2<br />

1.76<br />

thru<br />

3.52<br />

2.64<br />

thru<br />

7.03<br />

7.03<br />

thru<br />

17.6<br />

17.6<br />

thru<br />

35.2<br />

2.64<br />

thru<br />

3.52<br />

2.64<br />

thru<br />

7.03<br />

3.52<br />

thru<br />

17.6<br />

10.6<br />

thru<br />

26.4<br />

17.6<br />

thru<br />

42.2<br />

2.64<br />

thru<br />

7.03<br />

3.52<br />

thru<br />

7.03<br />

5.28<br />

thru<br />

17.6<br />

14.1<br />

thru<br />

35.2<br />

26.4<br />

thru<br />

52.8<br />

52.8<br />

52.<br />

8 35.<br />

2 52.<br />

8 70. 3<br />

W? Based on 30°C liquid line temperature and a refrigerant flow of 400 grams per minute per kW of Refrigerant 134a; 374 grams per minute per kW of Refrigerant 22; 503 grams per minute per kW for Refrigerant<br />

404A; 375 grams per minute per kW for Refrigerant 407C; 362 grams per minute per kW for Refrigerant 410A and 529 grams per minute per kW for Refrigerant 507. Ratings in accordance to ARI Standard 710.<br />

WZ 20 drops = 1 gram = 1cc.<br />

WX The filtration area is equal to the core surface area plus the large internal surface available for depth filtration.<br />

NOTE: R-12 water capacity values are approximately 15 percent greater than R-134a. R-502 water capacities are similar to R-404A and R-507.<br />

NOTE: The variation in flow ratings of filter-driers having the same size core and shell is caused by the difference in connection sizes used.<br />

For complete capacity and selection information refer to Bulletin 40-10.