2.3 Top Level Key Functions<br />

Operating controls for the <strong>Model</strong> <strong>1835</strong>-C are found on both the front and rear<br />

panels of the <strong>Model</strong> <strong>1835</strong>-C. For measurement operation, only the front panel<br />

controls are used. Rear panel controls are used for AC line power setup,<br />

Section 2.5.<br />

The front panel key pad of the <strong>Model</strong> <strong>1835</strong>-C, Figure 3, provides quick access<br />

to measurement functions and menu access to advanced features and setup<br />

parameters. Table 2 and Sections 2.3.1 through 2.3.12 list and describe each<br />

top level key function. Menu level key functions are discussed in Section 2.4.<br />

(LOCAL)<br />

SHIFT<br />

STO REF<br />

DISP<br />

ATTN<br />

FILTER<br />

λ<br />

ZERO<br />

RANGE<br />

AUTO<br />

O<br />

I<br />

EXT<br />

R/S<br />

MENU<br />

MODE<br />

ENTER<br />

UNITS<br />

ESC<br />

STATS<br />

5<br />

Figure 3. Front Panel Key Pad<br />

Table 2. Top Level Key Functions and Associated Remote Commands<br />

Keypad Remote Commands Description<br />

O I<br />

None<br />

Turn the <strong>Model</strong> <strong>1835</strong>-C on and<br />

off.<br />

SHIFT None Enable the blue key functions.<br />

DISP DISP, DISP? Cycle display brightness: OFF,<br />

LOW, NORM and HIGH.<br />

FILTER FILTER, FILTER? Cycle signal filtering: OFF,<br />

ANLG, DIG and ANLG+DIG.<br />

ZERO ZERO, ZERO?, STOZERO, Zero the display via offset<br />

ZEROVAL?<br />

subtraction.<br />

AUTO AUTO, AUTO? Turn automatic gain ranging on<br />

and off.<br />

STO REF STOREF, STOREF? Store last reading for future dB<br />

and REL measurements.<br />

ATTN ATTN, ATTN? Set responsivity to detector or<br />

detector-with-attenuator.<br />

λ LAMBDA, LAMBDA? Display and edit the calibration<br />

wavelength in use.<br />

RANGE RANGE, RANGE? Display signal gain range in use.<br />

R/S RUN, STOP Starts and stops signal<br />

acquisition.<br />

MODE MODE, MODE? Cycle meter between allowed<br />

measurement modes.<br />

UNITS UNITS, UNITS? Cycle display measurement<br />

units between those allowed.<br />

STATS STSIZE, STSIZE?, STMAX? Display statistics.: Max, Min,<br />

STMIN?, STMXMN? STMEAN Max-Min, Mean and Std. Dev.<br />

STSDEV?