BAUER<br />

COMPRESSORS<br />

Junior II, Yachting<br />

Figure 3-17<br />

Internal Air Flow Diagram; JRII Yachting<br />

Air<br />

Condensate<br />

12<br />

13<br />

1<br />

6<br />

14<br />

11<br />

9<br />

2<br />

3<br />

10<br />

19<br />

17<br />

8<br />

5<br />

4<br />

20<br />

18<br />

15<br />

18<br />

16<br />

15<br />

7<br />

1. Compressor Air Intake Extensions<br />

2. Intake Filter<br />

3. 1st Stage Cylinder<br />

4. 2nd Stage Cylinder<br />

5. 3rd Stage Cylinder<br />

6. 1st/2nd Stage Intercooler<br />

7. 2nd/3rd Stage Intercooler<br />

8. Intermediate Separator<br />

9. After Cooler<br />

10. 1st Stage Safety Valve<br />

11. 2nd Stage Safety Valve<br />

12. Final Pressure Safety Valve<br />

13. P0 Filter System<br />

14. Triplex ® Longlife Cartridge<br />

15. Manual Condensate Drain Valves<br />

16. Pressure Maintaining Valve<br />

17. Fill Hose<br />

18. Pneumatic Condensate Drain Valves<br />

19. ACD Separator<br />

20. ACD Separator Drain<br />

3.6.3 ACD Maintenance<br />

The condensate drain valves are provided with manual drain valves to verify correct operation of the<br />

automatic system.<br />

The automatic condensate drain system must be serviced once a week as follows:<br />

1. Open all manual drain valves one after the other.<br />