5.2.2.2 Chamber Replacement Interval<br />

^ NOTE ^<br />

The used filter cartridge must be disposed of in accordance with local regulations.<br />

^ WARNING ^<br />

The P0 Purification System is subject to dynamic loading. It is designed for a certain number of load<br />

cycles. A load cycle equates to an abrupt pressure loss caused by draining the condensate.<br />

The P0 Purification System must be replaced after reaching the maximum number of load cycles, otherwise<br />

the housing may fail due to material fatigue.<br />

The maximum number of load cycles for the P0 Purification Assembly is 45,000 if operated at 5,000<br />

psi (300 bar) or 63,000 if operated at 3,200 psi (225 bar).<br />

If the number of load cycles of four per hour (i.e. the condensate is drained every fifteen minutes) is not<br />

exceeded then the maximum number of operating hours before the P0 Purification System must be<br />

replaced is 11,250 hours at 5,000 psi (300 bar). To avoid exceeding the maximum number of load<br />

cycles the operating hours should always be recorded.<br />