Case #1: Implant Placement and Immediate Non-Functional Temporization<br />
The patient is a 46-year-old female who initially presented<br />
to our office with a chief complaint of: “I have a brokendown<br />
tooth that I would like to have extracted and replaced<br />
with an implant.” After evaluation of the patient, the crown<br />
of tooth #4 was found to be fractured, and decay was noted<br />
subgingivally. The tooth was determined to be nonrestorable,<br />
and was atraumatically extracted under local anesthesia,<br />
with care taken to preserve the buccal plate. The socket<br />
was gently currettaged and Puros ® Cortico-Cancellous Particulate<br />
Allograft material (Zimmer <strong>Dental</strong>; Carlsbad, Calif.)<br />
was placed in the extraction site for socket preservation and<br />
covered with a BioMend ® Absorbable Collagen Membrane<br />
(Zimmer <strong>Dental</strong>). The membrane was then secured using<br />
4-0 Vicryl ® suture (Ethicon Inc; Somerville, N.J.).<br />
After four months, the patient returned to our office for<br />
evaluation, during which the extraction site and graft were<br />
determined to have adequately matured to proceed with<br />
implant placement. After reviewing the CBCT scan in the<br />
In2Guide implant planning software (Cybermed Inc.;<br />
Irvine, Calif.), the decision was made to place a 3.7 mm x<br />
10 mm Inclusive ® Tapered Implant.<br />
1a<br />
The requisite polyvinyl siloxane impressions were taken, as well as an accurate bite registration and preoperative intraoral<br />
photographs, including selection of the shade for the BioTemps ® provisional crown.<br />
1b<br />
2<br />
The diagnostic records were submitted,<br />
along with a completed Inclusive Tooth<br />
Replacement Solution digital Rx, to<br />
<strong>Glidewell</strong> Laboratories for fabrication<br />
of the Inclusive Tooth Replacement<br />
Solution components. Upon receipt of the<br />
patient’s diagnostic records and digital<br />
Rx, the Inclusive Tooth Replacement<br />
Solution components were fabricated<br />
and forwarded to our office for implant<br />
placement and temporization.<br />
✔<br />
James Smith<br />
10-5217558<br />
drjsmith6585@yahoo.com<br />
123 Main Street Suite #1 Anywhere, USA<br />
Jane<br />
Doe<br />
✔<br />
4 A3<br />
Please fabricate components for replacement of #4.<br />
J Smith<br />
555-555-5555<br />
✔<br />
✔<br />
✔<br />
✔<br />
1265287<br />
✔<br />
✔ Shade photos<br />
54<br />
– www.inclusivemagazine.com –