TABLE 2<br />

COMBUSTIBLE FLOORING BASE OPENING SIZE<br />

Cabinet<br />

Width<br />

Catalog<br />

Number<br />

Front to Rear<br />

Side to Side<br />

in. mm in. mm<br />

FURNACE<br />

B Cabinet<br />

(17.5")<br />

11M60 22 559 18 − 3/4 476<br />

C Cabinet<br />

(21")<br />

11M61 22 559 22 − 3/4 578<br />

PROPERLY<br />

SIZED FLOOR<br />

OPENING<br />

COOLING COIL<br />

PLENUM<br />

FURNACE<br />

SUPPLY AIR<br />

PLENUM<br />

PROPERLY<br />

SIZED FLOOR<br />

OPENING<br />

FIGURE 13<br />

COMBUSTIBLE<br />

FLOORING BASE<br />

2 − After opening is cut, set the combustible flooring base<br />

into opening.<br />

3 − Check fiberglass strips on the combustible flooring<br />

base to make sure they are properly glued and positioned.<br />

4 − Lower supply air plenum into the combustible flooring<br />

base until plenum flanges seal against fiberglass<br />

strips.<br />

NOTE − Be careful not to damage fiberglass strips.<br />

Check for a tight seal.<br />

5 − Set the furnace over the plenum.<br />

6 − Ensure that the seal between the furnace and plenum<br />

is adequate.<br />

<strong>Installation</strong> on Cooling Coil Cabinet Figure 14<br />

NOTE − Downflow combustible flooring kit is not used..<br />

1 − Refer to reverse−flow coil installation instructions for<br />

correctly sized opening in floor and installation of cabinet.<br />

2 − When cooling cabinet is in place, set and secure the<br />

furnace according to the instructions that are provided<br />

with the cooling coil. Secure the furnace to the cabinet.<br />

3 − Seal the cabinet and check for air leaks.<br />

FIGURE 14<br />

Return Air Opening −− Downflow Units<br />

Return air may be brought in only through the top opening<br />

of a furnace installed in the downflow position. The following<br />

steps should be taken when installing plenum:<br />

1 − Bottom edge of plenum should be flanged with a<br />

hemmed edge (See figure 15 or 16).<br />

2 − Sealing strips should be used to ensure an airtight seal<br />

between the cabinet and the plenum.<br />

3 − In all cases, plenum should be secured to top of furnace<br />

using sheet metal screws.<br />

4 − Make certain that an adequate seal is made.<br />

PLENUM<br />

(Field Provided)<br />

SEALING STRIP<br />

(Field Provided)<br />

PLENUM<br />

(Field Provided)<br />

SECURE FROM<br />

INSIDE CABINET<br />

ÉÉÉÉ<br />

Side View<br />

FIGURE 15<br />

Side View<br />

ÉÉÉÉ<br />

FIGURE 16<br />

SECURE FROM<br />

OUTSIDE CABINET<br />

CABINET<br />

SIDE PANEL<br />

SEALING STRIP<br />

(Field Provided)<br />

CABINET<br />

SIDE PANEL<br />

Page 11