<strong>ML193DF</strong> and CONDENSING UNIT<br />

THERMOSTAT DESIGNATIONS<br />

(Refer to specific thermostat and outdoor unit.)<br />

Thermostat <strong>Furnace</strong> Condensing<br />

Unit<br />

R<br />

W1<br />

Y<br />

G<br />

C<br />

POWER<br />

HEAT<br />

COOLING<br />

INDOOR BLOWER<br />

COMMON<br />

R<br />

W<br />

Y<br />

G<br />

C<br />

*CONDENSING<br />

UNIT<br />

CONDENSING<br />

UNIT<br />

CONDENSING<br />

UNIT COMMON<br />

Install the room thermostat according to the instructions<br />

provided with the thermostat. See figure 50 for<br />

thermostat designations. If the furnace is being<br />

matched with a heat pump, refer to the FM21 installation<br />

instruction or appropriate dual fuel thermostat instructions.<br />

Indoor Blower Speeds<br />

1 − When the thermostat is set to FAN ON," the indoor<br />

blower will run continuously on the heating speed<br />

when there is no cooling or heating demand.<br />

2 − When the <strong>ML193DF</strong> is running in the heating mode,<br />

the indoor blower will run on the heating speed.<br />

3 − When there is a cooling demand, the indoor blower will<br />

run on the cooling speed.<br />

*NOTE − R" REQUIRED ON SOME OUTDOOR UNITS<br />

FIGURE 50<br />

TYPICAL <strong>ML193DF</strong> FIELD WIRING DIAGRAM<br />

IGNITOR<br />

*NOTE − R" REQUIRED ON SOME OUTDOOR UNITS<br />

*R<br />

FIGURE 51<br />