TYPICAL EXHAUST PIPE CONNECTIONS<br />
Pipe size determined in table 7.<br />
2”<br />
2”<br />
2”<br />
or<br />
2”<br />
2”<br />
3”<br />
TRANSITION<br />
*2”<br />
DO NOT transition from smaller<br />
to larger pipe size in horizontal<br />
runs of exhaust pipe.<br />
INTAKE<br />
EXHAUST<br />
TOP VIEW<br />
* When transitioning up in pipe size, use the shortest length of 2” PVC pipe possible.<br />
NOTE − Exhaust pipe and intake pipe must be the same diameter.<br />
FIGURE 20<br />
TYPICAL INTAKE PIPE CONNECTIONS<br />
Pipe size determined in table 7.<br />
2”<br />
2”<br />
2”<br />
or<br />
2”<br />
2”<br />
TRANSITION<br />
3”<br />
TRANSITION<br />
*2”<br />
*2”<br />
3”<br />
*2”<br />
INTAKE<br />
EXHAUST<br />
TOP VIEW<br />
* When transitioning up in pipe size, use the shortest length of 2” PVC pipe possible.<br />
NOTE − Intake pipe and exhaust pipe must be the same diameter.<br />
FIGURE 21<br />
Page 17