FIELD SUPPLIED WALL TERMINATION OR<br />

(15F74) WALL RING TERMINATION KIT<br />

FIELD SUPPLIED WALL TERMINATION OR<br />

(15F74) WALL RING TERMINATION KIT<br />

With INTAKE ELBOW<br />

NOTE − FIELD PROVIDED<br />

REDUCER MAY BE<br />

REQUIRED TO ADAPT<br />

LARGER VENT PIPE SIZE<br />

TO TERMINATION<br />

1/2" (13mm) ARMAFLEX<br />

INSULATION IN UN-<br />

CONDITIONED SPACE<br />

NOTE − FIELD PROVIDED<br />

REDUCER MAY BE<br />

REQUIRED TO ADAPT<br />

LARGER VENT PIPE SIZE<br />

TO TERMINATION<br />

1/2" (13mm) ARMAFLEX<br />

INSULATION IN UN-<br />

CONDITIONED SPACE<br />

SIZE TERMINATION<br />

PER TABLE 8<br />

SIZE TERMINATION<br />

PER TABLE 8<br />

D<br />

D<br />

C<br />

A<br />

B<br />

STRAIGHT<br />

APPPLICATION<br />

C<br />

A<br />

B<br />

STRAIGHT<br />

APPPLICATION<br />

1/2" (13mm) ARMAFLEX INSULATION<br />

IN UNCONDITIONED SPACE<br />

1/2" (13mm) ARMAFLEX INSULATION<br />

IN UNCONDITIONED SPACE<br />

* WALL<br />

SUPPORT<br />

E<br />

D<br />

B<br />

* WALL<br />

SUPPORT<br />

E<br />

B<br />

D<br />

C<br />

A<br />

EXTENDED<br />

APPLICATION<br />

C<br />

A<br />

EXTENDED<br />

APPLICATION<br />

See venting table 7 for maximum venting lengths with this<br />

arrangement.<br />

* Use wall support every 24" (610 mm). Use two wall supports if<br />

extension is greater than 24" (610 mm) but less than 48" (1219 mm).<br />

NOTE − One wall support must be 6" (152 mm) from top of each pipe<br />

(intake and exhaust)<br />

A−Minimum clearance<br />

above grade or average<br />

snow accumulation<br />

B−Maximum horizontal<br />

separation between<br />

intake and exhaust<br />

C−Minimum from<br />

end of exhaust to<br />

inlet of intake<br />

D−Maximum exhaust<br />

pipe length<br />

E−Maximum wall support<br />

distance from top of each<br />

pipe (intake/exhaust)<br />

2" (51mm)<br />

Vent Pipe<br />

FIGURE 28<br />

3" (76mm)<br />

Vent Pipe<br />

12" (508MM) 12" (508MM)<br />

6" (152MM) 6" (152MM)<br />

8" (203MM) 8" (203MM)<br />

12" (305MM) 20" (508MM)<br />

6" (152MM) 6" (152MM)<br />

See venting table 7 for maximum venting lengths with this<br />

arrangement.<br />

* Use wall support every 24" (610 mm). Use two wall supports if<br />

extension is greater than 24" (610 mm) but less than 48" (1219 mm).<br />

NOTE − One wall support must be 6" (152 mm) from top of each pipe<br />

(intake and exhaust)<br />

A−Minimum clearance<br />

above grade or average<br />

snow accumulation<br />

B−Maximum horizontal<br />

separation between<br />

intake and exhaust<br />

C−Minimum from<br />

end of exhaust to<br />

inlet of intake<br />

D−Maximum exhaust<br />

pipe length<br />

E−Maximum wall support<br />

distance from top of each<br />

pipe (intake/exhaust)<br />

2" (51mm)<br />

Vent Pipe<br />

FIGURE 29<br />

3" (76mm)<br />

Vent Pipe<br />

12" (508MM) 12" (508MM)<br />

6" (152MM) 6" (152MM)<br />

6" (152MM)<br />

6" (152MM)<br />

12" (305MM) 20" (508MM)<br />

6" (152MM) 6" (152MM)<br />

Page 23