FIELD SUPPLIED WALL TERMINATION OR<br />
(15F74) WALL RING TERMINATION KIT<br />
FIELD SUPPLIED WALL TERMINATION OR<br />
(15F74) WALL RING TERMINATION KIT<br />
With INTAKE ELBOW<br />
NOTE − FIELD PROVIDED<br />
REDUCER MAY BE<br />
REQUIRED TO ADAPT<br />
LARGER VENT PIPE SIZE<br />
TO TERMINATION<br />
1/2" (13mm) ARMAFLEX<br />
INSULATION IN UN-<br />
CONDITIONED SPACE<br />
NOTE − FIELD PROVIDED<br />
REDUCER MAY BE<br />
REQUIRED TO ADAPT<br />
LARGER VENT PIPE SIZE<br />
TO TERMINATION<br />
1/2" (13mm) ARMAFLEX<br />
INSULATION IN UN-<br />
CONDITIONED SPACE<br />
SIZE TERMINATION<br />
PER TABLE 8<br />
SIZE TERMINATION<br />
PER TABLE 8<br />
D<br />
D<br />
C<br />
A<br />
B<br />
STRAIGHT<br />
APPPLICATION<br />
C<br />
A<br />
B<br />
STRAIGHT<br />
APPPLICATION<br />
1/2" (13mm) ARMAFLEX INSULATION<br />
IN UNCONDITIONED SPACE<br />
1/2" (13mm) ARMAFLEX INSULATION<br />
IN UNCONDITIONED SPACE<br />
* WALL<br />
SUPPORT<br />
E<br />
D<br />
B<br />
* WALL<br />
SUPPORT<br />
E<br />
B<br />
D<br />
C<br />
A<br />
EXTENDED<br />
APPLICATION<br />
C<br />
A<br />
EXTENDED<br />
APPLICATION<br />
See venting table 7 for maximum venting lengths with this<br />
arrangement.<br />
* Use wall support every 24" (610 mm). Use two wall supports if<br />
extension is greater than 24" (610 mm) but less than 48" (1219 mm).<br />
NOTE − One wall support must be 6" (152 mm) from top of each pipe<br />
(intake and exhaust)<br />
A−Minimum clearance<br />
above grade or average<br />
snow accumulation<br />
B−Maximum horizontal<br />
separation between<br />
intake and exhaust<br />
C−Minimum from<br />
end of exhaust to<br />
inlet of intake<br />
D−Maximum exhaust<br />
pipe length<br />
E−Maximum wall support<br />
distance from top of each<br />
pipe (intake/exhaust)<br />
2" (51mm)<br />
Vent Pipe<br />
FIGURE 28<br />
3" (76mm)<br />
Vent Pipe<br />
12" (508MM) 12" (508MM)<br />
6" (152MM) 6" (152MM)<br />
8" (203MM) 8" (203MM)<br />
12" (305MM) 20" (508MM)<br />
6" (152MM) 6" (152MM)<br />
See venting table 7 for maximum venting lengths with this<br />
arrangement.<br />
* Use wall support every 24" (610 mm). Use two wall supports if<br />
extension is greater than 24" (610 mm) but less than 48" (1219 mm).<br />
NOTE − One wall support must be 6" (152 mm) from top of each pipe<br />
(intake and exhaust)<br />
A−Minimum clearance<br />
above grade or average<br />
snow accumulation<br />
B−Maximum horizontal<br />
separation between<br />
intake and exhaust<br />
C−Minimum from<br />
end of exhaust to<br />
inlet of intake<br />
D−Maximum exhaust<br />
pipe length<br />
E−Maximum wall support<br />
distance from top of each<br />
pipe (intake/exhaust)<br />
2" (51mm)<br />
Vent Pipe<br />
FIGURE 29<br />
3" (76mm)<br />
Vent Pipe<br />
12" (508MM) 12" (508MM)<br />
6" (152MM) 6" (152MM)<br />
6" (152MM)<br />
6" (152MM)<br />
12" (305MM) 20" (508MM)<br />
6" (152MM) 6" (152MM)<br />
Page 23