Structures System – Load Cells and Amplifiers<br />
Choice of Load Cell Amplifiers:<br />
CI.Load.Cell.Amplifier<br />
CI-6464<br />
Dual.Load.Cell.Amplifier<br />
PS-2205<br />
Load.Cell.Amplifier<br />
(6.ports)<br />
PS-2198<br />
This amplifier allows users of the 500<br />
and 750 ScienceWorkshop Interfaces to<br />
collect data using the Structures System<br />
100N and 5N Load Cells. This system has<br />
been successfully used at sample rates<br />
up to 10,000 Hz. The sample rate limit<br />
is determined by the interface and<br />
computer used.<br />
A separate amplifier is required for<br />
each load cell.<br />
Order Information:<br />
CI Load Cell Amplifier*................CI-6464<br />
Required for Use:<br />
ScienceWorkshop Interface....p..2<br />
Load.Cell.100N*..................................PS-2200.<br />
Load.Cell.5N*.......................................PS-2201.<br />
Also available at a discount:<br />
CI Load Cell and<br />
Amplifier Set*..........................CI-6465<br />
Set Includes:<br />
CI.Load.Cell.Amplifier*..<br />
(CI-6464)<br />
Load.Cell.100N*..<br />
(PS-2200)<br />
Required for use:<br />
ScienceWorkshop Interface.(p..2)<br />
Two types of Load Cells:<br />
The Amplifier accepts either the 100N load<br />
cell or the 5N load cell or a combination<br />
of both. The maximum data sample rate is<br />
1000 Hz for each port.<br />
A PASCO PASPORT USB interface is<br />
required: Use a USBLink (PS-2100A) for<br />
just one Load Cell Amplifier or use an<br />
Xplorer GLX (PS-2002) or PowerLink<br />
(PS-2001) for multiple Load Cell Amplifiers.<br />
Order Information:<br />
Dual Load Cell Amplifier*..........PS-2205<br />
Required for Use:<br />
PASPORT.Interface.........................p..4<br />
Load.Cell.100N*..................................PS-2200.<br />
Load.Cell.5N*.......................................PS-2201.<br />
Also available at a discount:<br />
Load Cell and<br />
Dual Amplifier Set*.............PS-2206<br />
Set Includes:<br />
Dual.Load.Cell.Amplifier*..<br />
(PS-2205)<br />
Load.Cell.100N*..<br />
(PS-2200)<br />
Required for use:<br />
PASPORT.Interface.(p..4)<br />
Load cells are available in two different ranges: ±100 N and ± 5 N. These load cells are<br />
designed to be inserted into structures without changing the length of the member. A load<br />
cell attached to two shorter beams is equal in length to a longer beam. Both types of load<br />
cells can be used with the same amplifier in any combination. The semi-transparent case<br />
lets students see the strain gauge and beam inside.<br />
This Load Cell Amplifier can accommodate<br />
up to six load cells and only needs a single<br />
USBLink (PS-2100A) to connect to the<br />
USB port on a computer. This is useful for<br />
doing an extensive analysis of a bridge by<br />
inserting six load cells at various points<br />
in the structure to see if theory matches<br />
reality.<br />
The Amplifier accepts either the 100N load<br />
cell or the 5N load cell or a combination<br />
of both. The maximum data sample rate is<br />
500 Hz for each port.<br />
Order Information:<br />
Load Cell Amplifier*<br />
(6 ports).................................................PS-2198<br />
Required for Use:<br />
PASPORT.Interface......................p..4<br />
Load.Cell.100N*...............................PS-2200.<br />
Load.Cell.5N*....................................PS-2201.<br />
Also available at a discount:<br />
Load Cell and<br />
Amplifier Set*..........................PS-2199<br />
Set Includes:<br />
Load.Cell.Amplifier*..<br />
(PS-2198)<br />
Load.Cell.100N*..<br />
(qty.4).(PS-2200)<br />
Required for use:<br />
PASPORT..<br />
Interface.(p..4)<br />
Load Cell 5N<br />
(PS-2201)<br />
Load.Cell.<br />
100N<br />
PS-2200<br />
Load.Cell.5N<br />
PS-2201<br />
Specifications<br />
Range: -100 N to +100 N<br />
Accuracy: ±1% (± 1 N)<br />
Resolution: 0.02 N<br />
Safe Overload: -150 N to +150 N<br />
Specifications<br />
Range: -5 N to +5 N<br />
Accuracy: ±1% (±0.05 N)<br />
Resolution: 0.001 N<br />
Safe Overload: -7.5 N to +7.5 N<br />
2 1/4”<br />
Load Cell 100N<br />
(PS-2200)<br />
Order Information:<br />
100 N Load Cell*...............PS-2200<br />
Order Information:<br />
5 N Load Cell*....................PS-2201<br />
www.pasco.com/engineering<br />
Mix 5N and 100N load cells on the same amplifier<br />
*Patents pending<br />
9