23.10.2014 Views

Download catalog - Saint-Tech

Download catalog - Saint-Tech

Download catalog - Saint-Tech

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Structures System – Load Cells and Amplifiers<br />

Choice of Load Cell Amplifiers:<br />

CI.Load.Cell.Amplifier<br />

CI-6464<br />

Dual.Load.Cell.Amplifier<br />

PS-2205<br />

Load.Cell.Amplifier<br />

(6.ports)<br />

PS-2198<br />

This amplifier allows users of the 500<br />

and 750 ScienceWorkshop Interfaces to<br />

collect data using the Structures System<br />

100N and 5N Load Cells. This system has<br />

been successfully used at sample rates<br />

up to 10,000 Hz. The sample rate limit<br />

is determined by the interface and<br />

computer used.<br />

A separate amplifier is required for<br />

each load cell.<br />

Order Information:<br />

CI Load Cell Amplifier*................CI-6464<br />

Required for Use:<br />

ScienceWorkshop Interface....p..2<br />

Load.Cell.100N*..................................PS-2200.<br />

Load.Cell.5N*.......................................PS-2201.<br />

Also available at a discount:<br />

CI Load Cell and<br />

Amplifier Set*..........................CI-6465<br />

Set Includes:<br />

CI.Load.Cell.Amplifier*..<br />

(CI-6464)<br />

Load.Cell.100N*..<br />

(PS-2200)<br />

Required for use:<br />

ScienceWorkshop Interface.(p..2)<br />

Two types of Load Cells:<br />

The Amplifier accepts either the 100N load<br />

cell or the 5N load cell or a combination<br />

of both. The maximum data sample rate is<br />

1000 Hz for each port.<br />

A PASCO PASPORT USB interface is<br />

required: Use a USBLink (PS-2100A) for<br />

just one Load Cell Amplifier or use an<br />

Xplorer GLX (PS-2002) or PowerLink<br />

(PS-2001) for multiple Load Cell Amplifiers.<br />

Order Information:<br />

Dual Load Cell Amplifier*..........PS-2205<br />

Required for Use:<br />

PASPORT.Interface.........................p..4<br />

Load.Cell.100N*..................................PS-2200.<br />

Load.Cell.5N*.......................................PS-2201.<br />

Also available at a discount:<br />

Load Cell and<br />

Dual Amplifier Set*.............PS-2206<br />

Set Includes:<br />

Dual.Load.Cell.Amplifier*..<br />

(PS-2205)<br />

Load.Cell.100N*..<br />

(PS-2200)<br />

Required for use:<br />

PASPORT.Interface.(p..4)<br />

Load cells are available in two different ranges: ±100 N and ± 5 N. These load cells are<br />

designed to be inserted into structures without changing the length of the member. A load<br />

cell attached to two shorter beams is equal in length to a longer beam. Both types of load<br />

cells can be used with the same amplifier in any combination. The semi-transparent case<br />

lets students see the strain gauge and beam inside.<br />

This Load Cell Amplifier can accommodate<br />

up to six load cells and only needs a single<br />

USBLink (PS-2100A) to connect to the<br />

USB port on a computer. This is useful for<br />

doing an extensive analysis of a bridge by<br />

inserting six load cells at various points<br />

in the structure to see if theory matches<br />

reality.<br />

The Amplifier accepts either the 100N load<br />

cell or the 5N load cell or a combination<br />

of both. The maximum data sample rate is<br />

500 Hz for each port.<br />

Order Information:<br />

Load Cell Amplifier*<br />

(6 ports).................................................PS-2198<br />

Required for Use:<br />

PASPORT.Interface......................p..4<br />

Load.Cell.100N*...............................PS-2200.<br />

Load.Cell.5N*....................................PS-2201.<br />

Also available at a discount:<br />

Load Cell and<br />

Amplifier Set*..........................PS-2199<br />

Set Includes:<br />

Load.Cell.Amplifier*..<br />

(PS-2198)<br />

Load.Cell.100N*..<br />

(qty.4).(PS-2200)<br />

Required for use:<br />

PASPORT..<br />

Interface.(p..4)<br />

Load Cell 5N<br />

(PS-2201)<br />

Load.Cell.<br />

100N<br />

PS-2200<br />

Load.Cell.5N<br />

PS-2201<br />

Specifications<br />

Range: -100 N to +100 N<br />

Accuracy: ±1% (± 1 N)<br />

Resolution: 0.02 N<br />

Safe Overload: -150 N to +150 N<br />

Specifications<br />

Range: -5 N to +5 N<br />

Accuracy: ±1% (±0.05 N)<br />

Resolution: 0.001 N<br />

Safe Overload: -7.5 N to +7.5 N<br />

2 1/4”<br />

Load Cell 100N<br />

(PS-2200)<br />

Order Information:<br />

100 N Load Cell*...............PS-2200<br />

Order Information:<br />

5 N Load Cell*....................PS-2201<br />

www.pasco.com/engineering<br />

Mix 5N and 100N load cells on the same amplifier<br />

*Patents pending<br />

9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!