EKG<br />
PS-2111<br />
The EKG Sensor measures electrical signals<br />
produced by the heart. As cardiac muscle<br />
depolarization and repolarization occurs,<br />
the EKG trace graphically illustrates the beating<br />
of the heart. The sensor comes with 100<br />
self-adhesive conductive patches that are<br />
easily removed from the skin after use.<br />
Typical Applications<br />
Generate a personal EKG graph<br />
Compare EKG graphs before and after mild<br />
exercise<br />
Specifications<br />
EKG Waveform:<br />
Voltage: 0 to 4.5 mV<br />
Resolution: 4.5 µV<br />
Sample Rate: 50 to 200 samples per second (sps)<br />
Default Sample Rate: 200 samples per second (sps)<br />
Heart Rate (Beats):<br />
Range: 47 to 250 beats per minute (bpm)<br />
Resolution: 1 beat per minute (bpm)<br />
Physiology Sensors<br />
HandGripHeartRate<br />
PS-2186<br />
The Hand Grip Heart Rate Sensor allows<br />
students to measure heart rate without<br />
the restriction and inconvenience of belts<br />
or clips. Extra long cords allow students<br />
to freely increase their physical activity<br />
in order to determine exercise heart rate.<br />
Simply grip the handles while the sensor<br />
measures cardiac muscle contraction in<br />
beats per minute.<br />
Typical Applications<br />
AP Biology Lab 10: Physiology of the Circulatory<br />
System<br />
Measure and compare resting, exercise and recovery<br />
heart rate to determine physical fitness levels<br />
Specifications<br />
Measurement Range: 40-240 beats per minute<br />
Time to acquire heart beat: 8-10 seconds<br />
Typ ical LED Indicators:<br />
Standby: handgrips not held<br />
Acquire: acquiring heart beat<br />
Beat: flashes with each beat<br />
BloodPressure<br />
PS-2207<br />
With PASCO’s Blood Pressure Sensor<br />
students easily measure heart rate (bpm),<br />
systolic and diastolic arterial blood pressure<br />
(mmHg). Students gain a greater understanding<br />
of the physiology of the circulatory<br />
system when they also learn about the<br />
physiology of blood pressure. The systolic<br />
and diastolic pressure provided in the digits<br />
display can be used by the student to verify<br />
their own determination of blood pressure<br />
from the graph.<br />
A student “patient” remains still while another student uses<br />
the pump to increase the pressure in the cuff. The students<br />
observe the graph as the pressure in the cuff slowly decreases.<br />
On the digits display, students observe the patient’s heart<br />
rate, systolic and diastolic blood pressure.<br />
NOTE: The EKG Sensor has been designed for educational<br />
purposes only and is not suitable for medical diagnoses.<br />
Order Information:<br />
Additional EKG Electrode<br />
Patches (CI-6620) may be<br />
ordered separately.<br />
EKG Sensor....................................................PS-2111<br />
EKG Patches (100 each).......................CI-6620<br />
Order Information:<br />
Heart Rate Sensor....................................PS-2186<br />
www.pasco.com/engineering<br />
Includes<br />
Blood Pressure Sensor, medium arm cuff*,<br />
bladder and pressure<br />
release valve.<br />
*small and large<br />
cuffs are also<br />
available<br />
Order Information:<br />
Blood Pressure Sensor.........................PS-2207<br />
Recommended:<br />
SmallCuff........................................................PS-2531<br />
MediumCuff..................................................PS-2532<br />
LargeCuff........................................................PS-2533<br />