1. Top Vent - Horizontal Termination - (continued)<br />
Three Elbows V 1<br />
+ V 2<br />
Minimum H 1<br />
+ H 2<br />
Maximum<br />
3 ft. 0.9 m 2 ft. 0.6 m<br />
4 ft. 1.2 m 4 ft. 1.2 m<br />
5 ft. 1.5 m 6 ft. 1.8 m<br />
12 ft. 3.7 m 20 ft. 6.1 m<br />
V 1<br />
+ V 2<br />
+ H 1<br />
+ H 2<br />
= 40 ft. (12.2 m) Maximum<br />
H 1<br />
+ H 2<br />
= 20 ft. (6.1 m) Maximum<br />
Note: V 1<br />
MUST be a minimum<br />
of 3 feet unless using the TAOS<br />
surround. For TAOS surround, V 1<br />
minimum MUST be 30 in.<br />
Note: The first elbow used<br />
MUST always be DVP90ST.<br />
Figure 5.5<br />
14<br />
Heat & Glo • Bravo • 704-902 Rev. D • 5/08