Note: Previous numbers are for combustible<br />

construction numbers. Arch may protrude up to<br />

5-1/2 inches maximum as measured from unit<br />

front face.<br />

OPTION C: SOUTHWESTERN kiva-style<br />

The third installation option illustrated is a corner-installation<br />

with custom fi nishing. This option requires advanced<br />

finishing methods involving either combustible or non-combustible<br />

construction materials (see Figure 11.7).<br />

Note: The kiva-style arch depth may be any size if<br />

using noncombustible materials i.e. concrete, steel,<br />

plaster, etc.<br />

• A template is provided on unit shipping carton.<br />

Simply cut along the line and use as a template when<br />

constructing kiva-style arch (see Figure 11.6).<br />

CAUTION<br />

Template for kiva-style arch represents MINIMUM inside<br />

dimensions. When constructing kiva-style arch, you must<br />

add thickness of fi nishing materials to achieve proper size<br />

of fi nished arch.<br />

Figure 11.7<br />

BACKING<br />

MATERIAL<br />

• A template is provided on the unit shipping carton.<br />

Simply cut along the line and use as a template for<br />

construction purposes.<br />

• The cardboard template provided represents MINIMUM<br />

inside dimensions of the fi nished wall surface.<br />

• If fi nishing with plaster or drywall, a fi nish edge trim is<br />

provided around door front on unit. Finishing materials<br />

MUST not extend inside of the fi nish edge trim.<br />

Figure 11.6<br />

FINISHING<br />

MATERIAL<br />

KIVA-STYLE ARCH<br />

STRUCTURE<br />

• Inside of the kiva-style arch can be fi nished using combustible<br />

materials. For example, thin drywall may be<br />

layered to form around curved arch.<br />

CAUTION<br />

Finishing materials cut inside the provided template or inside<br />

fi nish edge trim will cause the door not to fi t.<br />

Fire Risk.<br />

WARNING<br />

Follow minimum specifi ed clearances found in<br />

Section 16, (Appliance Dimensions Diagram)<br />

and on fi replace exterior if using combustible<br />

framing materials.<br />

34<br />