ON/OFF<br />

WALL SWITCH<br />

PLUG-IN<br />

3V TRANSFORMER<br />

IGNITION MODULE 3 VAC<br />

INTERMITTENT PILOT IGNITOR<br />

FLAME SPARKER/<br />

SENSOR<br />

IGNITION<br />

MODULE<br />

(3V)<br />

LOW VOLTAGE<br />

SEE NOTE 1.<br />

VALVE<br />

LOW VOLTAGE<br />

SEE NOTE 1<br />

NEUTRAL<br />

GROUND<br />

REMOTE<br />

CONTROL<br />

HOT<br />

GROUND TO<br />

FIREPLACE<br />

CHASSIS<br />

WHT<br />

ORG<br />

BLK<br />

RED<br />

BRN<br />

BRN<br />

ORG<br />

GRN<br />

BLACK WIRE CAN BE<br />

PLUGGED INTO ANY OF<br />

#1 - #5 LOCATIONS<br />

ON THE HOT SIDE<br />

WHITE WIRE CAN BE<br />

PLUGGED INTO ANY OF<br />

#1 - #5 LOCATIONS<br />

ON THE NEUTRAL SIDE<br />

TRANSFORMER<br />

3 VAC<br />

VALVE<br />

PLUG IN<br />

REMOTE JUMPER<br />

WIRE<br />

THERMOSTAT<br />

WIRE ASSEMBLY<br />

2045-045<br />

NOTE 1: IGNITION MODULE, VALVE, PILOT AND WALL SWITCH OPERATE ON 3 VOLTS.<br />

120 VAC IS REQUIRED AT JUNCTION BOX UNLESS EQUIPPED WITH BATTERY BACK-UP.<br />

Figure 10.1<br />

Intellifire Pilot Ignition (IPI) Wiring Diagram<br />

CAUTION<br />

Label all wires prior to disconnection when servicing controls.<br />

Wiring errors can cause improper and dangerous operation.<br />

Verify proper operation after servicing.<br />

WARNING<br />

Shock hazard.<br />

• Replace damaged wire with type 105 O C<br />

rated wire.<br />

• Wire must have high temperature insulation.<br />