11 Finishing<br />

A. Mantel Projections<br />

Figure 11.1 shows the minimum vertical and corresponding<br />

maximum horizontal dimensions of appliance mantels or<br />

other combustible projections above the top front edge of<br />

the appliance.<br />

1/2 INCH NON-COMBUSTIBLE<br />

BOARD REQUIRED ON UNIT FACE<br />

1 INCH<br />

MINIMUM<br />

TO<br />

VENT PIPE<br />

Note: All<br />

measurements<br />

in inches.<br />

18<br />

17<br />

16<br />

15<br />

14<br />

13<br />

12<br />

11<br />

10<br />

31/8<br />

9<br />

8<br />

7<br />

6<br />

37/8<br />

5<br />

31<br />

CEILING<br />

91/8<br />

MIN.<br />

FINISHING<br />

EDGE<br />

TRIM<br />

NAILING<br />

TABS<br />

TOP OF<br />

FINISHING STRIP<br />

TOP OF<br />

UNIT<br />

COMBUSTIBLE MATERIALS<br />

MAY CONTACT AND COVER<br />

FRONT AND SIDE AREAS<br />

BELOW GLASS/FRONT<br />

Figure 11.3 Noncombustible Facing Diagram<br />

Figure 11.1<br />

Clearances to Mantels or other Combustibles<br />

above Appliance<br />

WARNING<br />

Figure 11.2<br />

B. Facing Material<br />

Mantel Leg or Wall Projections<br />

(Acceptable on both sides of opening.)<br />

WARNING<br />

Fire Risk.<br />

Do NOT obstruct air inlet or outlet grilles.<br />

Do NOT modify grilles.<br />

• Modifying or covering grilles could cause<br />

temperature rise and fi re hazard.<br />

Finishing materials must not interfere with:<br />

• Air fl ow through grilles or louvers.<br />

• Operation of louvers or doors.<br />

• Access for service.<br />

Risk of Fire<br />

• Non-combustible clearances MUST be<br />

maintained.<br />

• Sheetrock, wood or other combustibles must<br />

NOT be used as sheathing or facing in the<br />

non-combustible zone.<br />

• See Section 11 for proper clearances.<br />

• See Section 1 for combustible/noncombustible<br />

defi nitions.<br />

WARNING<br />

Fire Risk.<br />

Finish all edges and fronts to clearances and<br />

specifi cations listed in manual.<br />

• Black metal appliance front may be covered with<br />

noncombustible material only.<br />

• Do NOT overlap combustible materials onto appliance<br />

front.<br />

• <strong>Install</strong> combustible materials only up to specifi ed clearances<br />

on top, front and side.<br />

• Seal joints between the fi nished wall and appliance top<br />

and sides using only a 300º F minimum sealant.<br />

32<br />