Jogging<br />

The rotary unit is jogged using the number buttons (0-9). Each number is a percent<br />

of the maximum speed. Jog speed is selected with the front panel number keys<br />

and is a fraction of the maximum feed rate.<br />

Select the axis to jog using the right arrow button on 2-axis units.<br />

If the control is set up for linear motion, there are both positive and negative travel<br />

limits possible. If a step is started which would have caused the control to exceed<br />

the travel limits, the following message is shown: 2 FAr<br />

The control will not execute the step. See Parameter 13 and 14 for the A-axis travel<br />

range, and Parameter 59 and 60 for the B-axis travel range.<br />

Error Codes<br />

A set of self tests are run when the control is turned on and the results may indicate<br />

a control fault. Intermittent low voltage errors or power failures may be the result<br />

of inadequate power to the controller. Use short heavy duty extension cords. Make<br />

sure that the supplied power is a minimum of 15 amps at the plug.<br />

Blank front panel - Program CRC failure (bad RAM, or cycle power if bad ROM to<br />

RAM program transfer.)<br />

E0 EProm - EPROM CRC error<br />

Frt Pnel Short - Front panel switch closed or shorted<br />

Remote Short - Remote Start switch closed and enabled, or remote CNC input<br />

shorted (remove cable to test)<br />

RAM Fault - Memory fault<br />

Stored Prg Flt - Stored program fault (low battery)<br />

Power Failure - Power failure interrupt (low line voltage)<br />

Enc Chip Bad - Encoder chip bad<br />

Interrupt Flt - Timer/interrupt fault<br />

1kHZ Missing - Clock generation logic failure (1 kHz signal missing)<br />

Scal Cmp Lrge - Exceeding maximum allowed rotary scales compensation.<br />

HRT210SC only<br />

0 Margin Small - (Zero margin too small) Distance between the home switch<br />

and the final motor position, after seeking home, is either less than 1/8 or greater<br />

than 7/8 of a motor revolution. This alarm occurs while homing the rotary table.<br />

Parameter 45, for the A-axis or Parameter 91 for the B-axis must be set properly.<br />

Use the default value (0) for the axis parameter (45 or 91) and add 1/2 of a motor<br />

revolution. 1/2 motor revolution is calculated by taking the value in Parameter 28<br />

for the A-axis, or Parameter 74 for the B-axis and dividing by 2. Enter this value for<br />

parameter 45 or 91 and re-home the rotary table.<br />

96-0315 Rev P<br />

April 2012<br />

29<br />

Original Instructions