CT<br />

CD<br />

CE<br />

Performance <strong>and</strong><br />

functionality<br />

Communication<br />

Communication architecture<br />

The (COM) communication option is<br />

required for integration of the <strong>circuit</strong><br />

breaker or <strong>switch</strong>-disconnector in a<br />

supervision system.<br />

Masterpact uses Modbus or Jbus<br />

communications protocol for full<br />

compatibility with SMS PowerLogic<br />

(electrical network) management systems.<br />

An external gateway is available for<br />

communication over ethernet networks.<br />

COM communication option<br />

For fixed devices, the COM option comprises of a communication module installed<br />

within the device <strong>and</strong> supplied by a set of sensors (OF, SDE ,PF <strong>and</strong> CH microcontacts)<br />

kit for connection to XF <strong>and</strong> MX communicating voltage releases.<br />

For drawout devices, the COM option comprises of:<br />

c A communication module within in the device <strong>and</strong> supplied by a set of<br />

auxilliaries (OF, SDE, PF <strong>and</strong> CH micro-contacts) <strong>and</strong>/or a kit for connection to<br />

XF <strong>and</strong> MX communicating voltage releases.<br />

c A communication module installed on the chassis <strong>and</strong> supplied by a set of<br />

sensors (CE, CD <strong>and</strong> CT contacts).<br />

Each installed device has an address that is assigned via the keypad of the control<br />

unit (Modbus) or remotely (Batibus). The address of a drawout device is assigned<br />

to the chassis which maintains the same address if the device is replaced.<br />

Status indication by the COM option is independent of the auxiliary indication<br />

contacts. These contacts remain available for conventional uses.<br />

“Device” communication module<br />

This module is independent of the control unit. Installed in the device, behind the<br />

control unit, it receives <strong>and</strong> transmits information on the communication network.<br />

An infra-red link transmits data between the control unit <strong>and</strong> the communication<br />

module.<br />

Consumption: 100 mA.<br />

“Chassis” communication module<br />

Installed on the chassis, this module makes it possible to address the chassis <strong>and</strong><br />

to maintain the address when the <strong>circuit</strong> breaker is in the disconnected position.<br />

Consumption: 100 mA.<br />

XF <strong>and</strong> MX communicating voltage releases<br />

The XF <strong>and</strong> MX communicating voltage releases are equipped for connection to<br />

the “device” communication module.<br />

The remote-tripping function (second MX or MN) is independent of the<br />

communication option.<br />

Communication architecture<br />

E45183 056431<br />

Modbus «device»<br />

communication module<br />

Communication<br />

bus<br />

2<br />

OF<br />

SDE<br />

PF<br />

CH<br />

CD<br />

CCM modbus<br />

+ +<br />

+<br />

CT<br />

MX<br />

XF<br />

CE<br />

4<br />

5<br />

6<br />

1<br />

Modbus «chassis»<br />

communication module<br />

COM<br />

module<br />

3<br />

1 “Device” communication module<br />

2 “Chassis” communication module<br />

3 OF, SDE, PF <strong>and</strong> CH «device» auxilliaries<br />

4 CE, CD <strong>and</strong> CT «chassis» auxilliaries<br />

5 MX <strong>and</strong> XF releases<br />