HYLOAD DPC AND CAVITY TRAY SYSTEMS 21<br />
Concrete wall<br />
tanking/DPC link detail<br />
Ruberoid High<br />
Performance DPC<br />
Ruberoid Plasprufe<br />
2000SA membrane<br />
Cavity fill<br />
Ruberoid Self-Adhesive<br />
Primer<br />
<strong>Hyload</strong> DPC Jointing Tape<br />
on Ruberoid Self Adhesive<br />
Primer<br />
Ruberoid High<br />
Performance DPC<br />
<strong>Hyload</strong> DPC Jointing Tape<br />
Ruberoid Self<br />
Adhesive Primer<br />
Ruberoid Plasprufe Protection Board<br />
Ruberoid Plasprufe 2000SA membrane<br />
Ruberoid Column Preformed<br />
Cloak Unit<br />
<strong>Hyload</strong> DPC Mastic<br />
<strong>Hyload</strong> DPC Jointing System<br />
Steel column<br />
Ruberoid High<br />
Performance DPC<br />
DPCs must project 5 mm beyond<br />
the external face and must be<br />
bedded on both faces with<br />
mortar.<br />
All joints between lengths of DPC,<br />
and DPC and Preformed Cloak<br />
Units must be lapped a minimum<br />
of 100 mm and bonded with<br />
<strong>Hyload</strong> DPC Lap Adhesive or<br />
<strong>Hyload</strong> DPC Jointing Tape.<br />
The cavity tray should step down<br />
or slope across the cavity not less<br />
than 150 mm towards the<br />
external leaf.<br />
Insulation omitted for clarity.<br />
Technical hotline: 0800 587 7391 www.ruberoid.co.uk