HYLOAD DPC AND CAVITY TRAY SYSTEMS 25<br />

<strong>Hyload</strong> DPC<br />

Fixing Strip and<br />

Fixing Pins for<br />

Masonry<br />

Window arch<br />

Ruberoid Arch Preformed Cloak Unit<br />

<strong>Hyload</strong> DPC<br />

Jointing Tape on<br />

Ruberoid Self-Adhesive<br />

Primer, alternatively<br />

<strong>Hyload</strong> DPC mastic<br />

can be used<br />

DPCs must project 5 mm beyond the<br />

external face and must be bedded on<br />

both faces with mortar.<br />

All joints between lengths of DPC, and<br />

DPC and Preformed Cloak Units must<br />

be lapped a minimum of 100 mm and<br />

bonded with <strong>Hyload</strong> DPC Lap Adhesive<br />

or <strong>Hyload</strong> DPC Jointing Tape.<br />

The cavity tray should step down or<br />

slope across the cavity not less than<br />

150 mm towards the external leaf.<br />

Insulation omitted for clarity.<br />

Technical hotline: 0800 587 7391 www.ruberoid.co.uk