HYLOAD DPC AND CAVITY TRAY SYSTEMS 23<br />

Protection against<br />

ground gases<br />

<strong>Hyload</strong> Original or<br />

Permabit DPC cavity tray<br />

DPCs must project 5 mm beyond the<br />

external face and must be bedded on<br />

both faces with mortar.<br />

All joints between lengths of DPC, and<br />

DPC and Preformed Cloak Units must<br />

be lapped a minimum of 100 mm and<br />

bonded with <strong>Hyload</strong> DPC Lap Adhesive<br />

or <strong>Hyload</strong> DPC Jointing Tape.<br />

The cavity tray should step down or<br />

slope across the cavity not less than<br />

150 mm towards the external leaf.<br />

Insulation omitted for clarity.<br />

Gastite DPC supported<br />

across the cavity<br />

Gastite DPM or<br />

Gastite LL<br />

Typical horizontal<br />

movement joint<br />

Typical vertical<br />

movement joint<br />

Ruberoid recommends where<br />

ever possible that DPCs do not<br />

span vertical movement joints.<br />

Ruberoid High Performance DPC<br />

Ruberoid Type 3<br />

Preformed Cloak Unit<br />

Technical hotline: 0800 587 7391 www.ruberoid.co.uk