<strong>Sensor</strong>+ Dimming System Features<br />

Play back Presets from the CEM+<br />

The CEM+ module provides 128 Presets that can be recorded from EDMX, DMX, or directly<br />

set levels. You can configure each Preset’s name, fade times and playback priority. Presets can<br />

be assigned to any one of four Rooms in the configuration. <strong>Sensor</strong>+ systems can also have the<br />

Group play back a Preset in case of data loss.<br />

<strong>Sensor</strong>+ Connect for Feedback<br />

<strong>Sensor</strong>+ Connect duplicates the functions of the CEM+ module on a PC or Emphasis<br />

Server on the <strong>ETC</strong>Net2 network. The Web browser interface allows you to monitor <strong>rack</strong><br />

activity, reconfigure <strong>dimmer</strong> curves, record and activate presets, load and backup<br />

configurations, and many other features.<br />

Access to the CEM+ and <strong>Sensor</strong>+ Connect configuration features is protected by specific<br />

user levels and passwords to limit system-altering features to selected personnel, while<br />

allowing basic operational functions to a wider range of users.<br />

Note:<br />

<strong>Sensor</strong>+ Connect and Message logging are available on Emphasis Servers as a base<br />

functionality.<br />

Advanced Features<br />

<strong>Sensor</strong>+ Advanced Features (AF) <strong>rack</strong>s provide additional reporting features that help you<br />

to quickly learn the status of your dimming system and diagnose problems. AF <strong>dimmer</strong><br />

modules indicate the presence of data and the relative output of power with LED indicators<br />

on the modules themselves. Much more information can be displayed on the CEM+<br />

module’s integral LCD display or a PC on the network running <strong>Sensor</strong>+ Connect in a web<br />

browser.<br />

Advanced Features provides the ability to record and monitor individual <strong>dimmer</strong> loads,<br />

provide error messages such as <strong>dimmer</strong> removed, SCR fail, breaker trip and other<br />

monitoring tools. Constant comparison of actual <strong>dimmer</strong> loads against the recorded value<br />

lets the system signal you when a load value changes. The change usually indicates a lamp<br />

has burned out or failed, allowing you to make an immediate replacement.<br />

Dimmer Doubling (60Hz systems only)<br />

<strong>ETC</strong>’s Dimmer Doubler technology allows you to double the number of controllable<br />

circuits in your system without adding <strong>dimmer</strong> modules or running additional cable. The key<br />

to this feature is the Dimmer Doubler two-fer.<br />

The Dimmer Doubler two-fer is installed between a <strong>Sensor</strong> <strong>dimmer</strong> module and two <strong>ETC</strong><br />

Source Four 77 volt fixtures. It splits the output of a single <strong>dimmer</strong> into two, separatelycontrolled<br />

outputs. You can then use an <strong>ETC</strong> control console to independently control the<br />

output of the two fixtures.<br />