Record vs. Snapshot a Preset<br />
Record and Snapshot are two different operations.<br />
Record will only use level information from Set Levels from the CEM+ modules in the group<br />
when storing a preset.<br />
Snapshot will use level information from all available sources to the CEM+ modules<br />
(DMXA, DMXB, EDMX, and Set Levels) when storing a preset.<br />
Activate/Deactivate a Preset<br />
Panic<br />
You can toggle any preset on or off from either the web interface or the face panel. Stations<br />
are also supported for preset activation, deactivation and recording. Please see<br />
Appendix B: SmartLink Stations Enabled on page 55 for more information on SmartLink<br />
stations.<br />
Max Active Presets<br />
Maximum Active Presets defines how many presets can be active in any one given room<br />
at a time. It can be set from a minimum of one (1) and to a maximum of four (4) at a time.<br />
Activating one preset more than allowable by Max Active Presets will deactivate the active<br />
preset with the lowest priority or if all active presets are at the same priority, the oldest<br />
previously activated priority.<br />
Max Active Presets defaults to one (1) which results in a “last action” activation/<br />
deactivation manner. (Turning on one preset turns off the previous preset.)<br />
Panic is configurable for different external switch action types (maintained vs. momentary)<br />
and switch resting states (normally-open vs. normally-closed). Panic always operates at the<br />
highest priority in the CEM+ and no other control source can pile-on with it or override it.<br />
Record Panic<br />
Create the desired panic look by setting <strong>dimmer</strong> levels from the CEM+ or from a external<br />
control source. Keep in mind that the Master Level acts as an intensity threshold for<br />
<strong>dimmer</strong>s and determines whether or not they are included in the panic. Only <strong>dimmer</strong>s with<br />
an intensity level equal to or greater than the Master Level will be included in Panic. When<br />
Panic is active, the <strong>dimmer</strong>s will also playback at the set Master Level.<br />
Set the Panic Master Level to your desired level (80% to 100%).<br />
Enable Force Others Off if you want load shedding to occur when Panic becomes active.<br />
What this means is when Panic becomes active, any <strong>dimmer</strong>s that are not included in Panic<br />
will be turned off.<br />
Lastly, record Panic.<br />
Activate Panic<br />
Panic can be activated via an external switch closure or locally via the face panel menu. It<br />
cannot be activated/deactivated via the web interface. Deactivation is also done by a switch<br />
closure (or lack of one, depending on the switch action type) or locally via the face panel<br />
menu.<br />