NoConfig<br />
About<br />
The NoConfig menu provides a place to make initial base settings and begin to create a<br />
configuration for the local CEM+. The NoConfig menu has no login requirements and<br />
anyone has access to these menu items.<br />
Generate Defaults<br />
The Generate Defaults menu allows you to create an initial configuration for your local <strong>rack</strong>.<br />
You can set your group and <strong>rack</strong> numbers along with <strong>rack</strong> type and <strong>dimmer</strong> information.<br />
However, you can only add multiple <strong>rack</strong>s of the same type. Additional <strong>rack</strong>s or <strong>rack</strong> types<br />
must be added later via the Add Racks menu item. For the face panel menu see Add Rack<br />
[Power], page 15 and for the web interface see Add Racks, page 22.<br />
• The first menu option within generate defaults allows you to choose between the main<br />
modes of operating feature sets. Options are Full Feature or Basic/Portable. This is a<br />
fundamental configuration mode choice. Basic/Portable mode provides a subset of full<br />
feature functionality for use in simple touring applications. For more info see Basic/<br />
Portable Mode, page 53.<br />
• Rack Types: SRxx is the U.S. style perminent installation <strong>rack</strong> and SPxx is the U.S.<br />
style type of portable <strong>rack</strong> (including touring <strong>rack</strong>s). ESRxx and ESPxx are for<br />
European installation <strong>rack</strong>s and portable <strong>rack</strong>s respectively. In all cases, the “xx”<br />
number is determined by the number of slots in the <strong>rack</strong> for modules (not the number<br />
of <strong>dimmer</strong>s).<br />
Set Group/Rack/Net<br />
The Set Group / Rack menu allows you to set the <strong>rack</strong> number of your local <strong>rack</strong> and the<br />
group number it belongs to. It also provides a place to set the network information (IP<br />
address, subnet mask and gateway IP). This should be done before creating a<br />
configuration. Changing this information may require the CEM+ to reboot to take effect.<br />
Get Config From<br />
After selecting this function, you will be prompted with the name of the <strong>rack</strong> you want to get<br />
the configuration from.<br />
Options will include:<br />
• Racks [1-16] which refers to any of the other <strong>rack</strong>s that may be online and configured<br />
as being from the same group.<br />
• FTP Server which refers to an FTP server if one is configured on your lighting network.<br />
It will ask you to specify the server’s IP address. Please see the section FTP Server,<br />
page 45 for more information about setting up an FTP server for use with CEM+.<br />
• Backplane (Stored in Rack) which refers to the configuration information stored in the<br />
back plane of the local <strong>rack</strong>.<br />
Once the configuration source has been chosen, it will transfer the configuration to the local<br />
CEM+. After the transfer is complete, you will get a confirmation or error message for the<br />
transfer.<br />
The About menu provides status information about the <strong>dimmer</strong>s, <strong>rack</strong>s, network and Group.<br />
Everything in the About menu is accessible by all users. No settings can be changed within<br />
the About menu. Data can only be viewed.<br />
Dimmer<br />
About Dimmer provides information about a selected <strong>dimmer</strong>, including recorded and<br />
actual loads, the <strong>dimmer</strong> type, curve and maximum voltage. You can also view the current<br />
output level, the source of that level, and the <strong>dimmer</strong>’s location.<br />
2 Basic Navigation 9