• Every Group of <strong>rack</strong>s must have a Rack 1.<br />

• Racks must be added sequentially, starting with <strong>rack</strong> 1 to a maximum of 16 <strong>rack</strong>s.<br />

• For European <strong>rack</strong> and module options, set the voltage to 240V.<br />

• [FP] This is straightforward in the face panel menu (it’s the first setting).<br />

• [Web] However, the web interface requires that you click the 240V check box then<br />

Save Changes before the options will change. The first click of Save Changes<br />

after altering the 240V setting will not add another <strong>rack</strong> (it changes the options), the<br />

next click of Save Changes will add the specified <strong>rack</strong>(s).<br />

• Rack Types: SRxx is an permanent installation <strong>rack</strong> and SPxx is any type of portable<br />

<strong>rack</strong> (including touring <strong>rack</strong>s). ESRxx and ESPxx are for European installation <strong>rack</strong><br />

and portable <strong>rack</strong>s respectively. In all cases, the “xx” number is determined by the<br />

number of slots in the <strong>rack</strong> for modules (not the number of <strong>dimmer</strong>s).<br />

Port Settings<br />

Patch by default gives every port on every <strong>rack</strong> a starting address and sequentially<br />

addresses the rest of the <strong>dimmer</strong>s in the <strong>rack</strong> from that point. To edit the <strong>dimmer</strong>’s<br />

addressing individually, change to the Patch tab where all of the patch data is exposed.<br />

By default every <strong>rack</strong> added will be set to an incremental DMX address starting at one (1)<br />

and continuing with the next available DMX channel available with only port A enabled on<br />

each <strong>rack</strong> (Port B and EDMX are disabled by default).<br />

You can edit the DMX start channel for each <strong>rack</strong> from the Patch/Port Settings page. You<br />

can enable/disable the data ports here as well.<br />

Note:<br />

To output DMX from port B of the last <strong>rack</strong> BOTH the checkbox for “Enable Port<br />

B Output” and the checkbox to enable port B on the last <strong>rack</strong> must be checked for<br />

this to work.<br />

Port B DMX Output is only available from the last logical <strong>rack</strong> in a group,<br />

regardless of its physical position within the group.<br />

This is also where you set the data priority and data loss behavior for each port of each <strong>rack</strong>.<br />

Priority is the preference given to each control source internally to the CEM+ (it is not<br />

broadcast to other <strong>ETC</strong>Net2 devices, nor does it use the source device’s priority once<br />

inside the CEM+) Priorities can be set for each port of each <strong>rack</strong> as well as recorded<br />

Presets. Data Loss Behavior tells the port what you want to happen when data is no<br />

longer being received on that port.<br />

CAUTION:<br />

An EDMX port will not currently go into a specified data loss behavior. If all EDMX<br />

is lost, the <strong>dimmer</strong>s will maintain the last known level until they have new level<br />

information to use.<br />

Patch<br />

The Patch page provides a powerful and convenient place to alter the default 1 to 1 patch<br />

to suit your individual needs. The patch itself is a table of addresses that you can use to<br />

assign various control channels (DMX and/or EDMX) to individual <strong>dimmer</strong>s. The <strong>dimmer</strong><br />

number and name are in the columns to the left and the rest of the row are the control<br />

channels that are patched to that <strong>dimmer</strong>. Control addresses must be limited to their<br />

respective valid ranges. Valid DMX range is 1 through 512. Valid EDMX range is 1 through<br />

32767. If your patching causes the range to exceed either of the valid maximums, the<br />

remainder of the specified <strong>dimmer</strong>s will remain unpatched.<br />

Dimmer Doubled addresses are always shown in patch, however <strong>dimmer</strong>s are not actually<br />

in <strong>dimmer</strong> doubling mode unless they are set with a Dimmer Double firing mode.<br />