Rack Split<br />

Patch Dimmers<br />

[Rack Split]<br />

Select Rack 1/ 1<br />

[Nnnnnnnnnnnnnnnn]<br />

Port A Dimmers<br />

From [xxxxx] to [yyyyy]<br />

Patch DMXA<br />

From [xxx] to >yyy<<br />

Port B Dimmers<br />

From [xxxxx] to [yyyyy]<br />

Patch DMXB<br />

From [rrr] to >sss<<br />

This method allows you to pick a <strong>rack</strong>, a range of <strong>dimmer</strong>s to assign to DMX Port A, then a<br />

range of addresses from Port A to assign them to. It then does the same for DMX Port B.<br />

This is mainly used when using two separate sources to control different portions of the<br />

same <strong>dimmer</strong> <strong>rack</strong>.<br />

By Ranges<br />

Patch Dimmers<br />

[By Ranges]<br />

Patch Dimmer Ranges<br />

To [DMXA]<br />

Patch Range<br />

From Dimmer [xxxxx]<br />

Patch Range<br />

Thru Dimmer [yyyyy]<br />

Press back or home key to exit<br />

Dimmersxxxxx-yyyyy<br />

To DMXA [xxx]<br />

Enter or 3 second timer<br />

Dim xxxxx-yyyyy A<br />

DMXA xxx - yyy<br />

This method allows you total control over patching ranges or individual <strong>dimmer</strong>s to ranges<br />

of addresses or non-sequential individual addresses via the face panel.<br />

Step 1: Choose the port (DMX A, DMX B or EDMX) you want to patch.<br />

Step 2: Choose the first <strong>dimmer</strong> number you want to patch<br />

Step 3: Choose the last <strong>dimmer</strong> number you want to patch. If the last <strong>dimmer</strong> number is<br />

the same as the first <strong>dimmer</strong> number, you will only patch a single <strong>dimmer</strong>.<br />

Step 4: Choose the first address of the previously choosen port to begin assigning to<br />

those <strong>dimmer</strong>s. This will be done sequentially from the first to last <strong>dimmer</strong><br />

choosen or until you run out of addresses by going beyond valid maximum range.<br />

DMX has a valid range of 1 to 512 and EDMX has a valid range of 1 to 32767.<br />

Step 5: Repeat Step 2 through Step 4 until your patching is complete.<br />

Step 6: Press the button or button to exit.<br />

Data Port & Priority<br />

The Data Port & Priority menu allows you to choose the <strong>rack</strong> and port (DMX A, DMX B or<br />

EDMX) and set the control priority to be used in determining the control source or sources<br />

for HTP. Priorities have a range from 20 (lowest) to 1 (highest). All ports default to 10 along<br />

with other <strong>ETC</strong> products so that the default control state is HTP. You can also enable or<br />

disable the data ports from this menu.<br />

Data Loss Behavior<br />

Data Loss Behavior can be set independently for each input port (DMX A, DMX B and<br />

EDMX) in each <strong>rack</strong> in the Group. Data loss behavior options are: Hold Last Look, Wait &<br />

Fade Out and Play Preset. When data is restored, the source look will fade in at a 2-second<br />

rate.<br />

• Hold Last Look: the CEM+ will hold any active <strong>dimmer</strong>s at whatever levels they were<br />

receiving when the data was lost. The <strong>dimmer</strong>s will remain on until data is restored or<br />

the CEM+ is reset.<br />

• Wait & Fade: the CEM+ will hold any active <strong>dimmer</strong>s at whatever levels they were<br />

receiving when the data was lost for a user-defined amount of time and then fade those<br />

<strong>dimmer</strong>s to zero (or to the levels generated by the next highest priority source) in a<br />

user-defined fade time. The maximum wait and fade time is 60:59 minutes.<br />

2 Basic Navigation 13