Optional Automatic Proximity Sensor Cutout Switch<br />

2 SENSOR TARGETS<br />

AT 180° IN COVER<br />

DRIVEN SHAFT<br />

DRIVING<br />

SHAFT<br />

AIR GAP<br />

2,29- 3,048<br />

25,4<br />

SENSOR<br />

TARGET<br />

CONTROL BOX<br />

T41 HUB<br />

SENSOR<br />

HEAD<br />

JAM NUT<br />

CABLE TO<br />

MOTOR<br />

SENSOR SUPPORT BRACKET<br />

An automatic proximity cutout switch in the motor starter control<br />

circuit of controlled torque coupling or clutch application is<br />

recommended for protection of connected equipment and<br />

coupling or clutch where damaging thermal buildup could<br />

develop. Refer to Slip Torque Performance Charts on Pages 22<br />

through 25 to determine if an automatic proximity sensor cutout<br />

switch is required.<br />

The proximity cutout switch speed control is adjustable at the<br />

control box. It is set at a required cutout speed and continually<br />

compares the actual speed of the driven shaft with the set cutout<br />

speed. The control box can be mounted in an approximate space<br />

of 76,2 millimeters wide by 76,2 millimeters deep by 127,0<br />

millimeters high.<br />

During overload, the coupling or clutch slips at a predetermined<br />

speed. When the driven shaft speed drops below the cutout<br />

switch speed setting, it opens the motor circuit and the drag load<br />

stops the motor shaft.<br />

When the underspeed cutout switch is wired for automatic reset,<br />

the drive is immediately ready for service (after overload is<br />

removed) without resetting the circuit at any point. To restart the<br />

drive, just press either the main or remote control start button.<br />

The motor will not maintain normal operation if the overload has<br />

not been removed because the motor contractor circuit will<br />

reopen as soon as the start button is released.<br />

The customer may incorporate a warning light or an alarm to the<br />

circuit to signal the operator of an overload or shutdown<br />

condition.<br />

Refer to Service Manual 428-440 for complete details.<br />

Overhanging Hubs<br />

When the distance between shaft ends is greater than the<br />

Coupling gap or when the coupling or clutch hub length is<br />

greater than the usable shaft length, overhang one or both hubs.<br />

For Type T41, if this results in less than one shaft diameter of hub<br />

engagement, check key stresses or use a semi-standard long T<br />

hub listed in Table 21, Page 39 or submit application details to<br />

Falk.<br />

CAUTION: The effect of open keyways on coupling or clutch<br />

balance should always be considered.<br />

Dimension Y must be equal to<br />

or greater than dimension X<br />

for clearance fits, or greater<br />

than Dimension X times .75<br />

for interference fits.<br />

X<br />

X<br />

Y<br />

Y<br />

© The Falk Corporation, 2003 (M421-110) 21