Optional Automatic Proximity Sensor Cutout Switch<br />
2 SENSOR TARGETS<br />
AT 180° IN COVER<br />
DRIVEN SHAFT<br />
DRIVING<br />
SHAFT<br />
AIR GAP<br />
2,29- 3,048<br />
25,4<br />
SENSOR<br />
TARGET<br />
CONTROL BOX<br />
T41 HUB<br />
SENSOR<br />
HEAD<br />
JAM NUT<br />
CABLE TO<br />
MOTOR<br />
SENSOR SUPPORT BRACKET<br />
An automatic proximity cutout switch in the motor starter control<br />
circuit of controlled torque coupling or clutch application is<br />
recommended for protection of connected equipment and<br />
coupling or clutch where damaging thermal buildup could<br />
develop. Refer to Slip Torque Performance Charts on Pages 22<br />
through 25 to determine if an automatic proximity sensor cutout<br />
switch is required.<br />
The proximity cutout switch speed control is adjustable at the<br />
control box. It is set at a required cutout speed and continually<br />
compares the actual speed of the driven shaft with the set cutout<br />
speed. The control box can be mounted in an approximate space<br />
of 76,2 millimeters wide by 76,2 millimeters deep by 127,0<br />
millimeters high.<br />
During overload, the coupling or clutch slips at a predetermined<br />
speed. When the driven shaft speed drops below the cutout<br />
switch speed setting, it opens the motor circuit and the drag load<br />
stops the motor shaft.<br />
When the underspeed cutout switch is wired for automatic reset,<br />
the drive is immediately ready for service (after overload is<br />
removed) without resetting the circuit at any point. To restart the<br />
drive, just press either the main or remote control start button.<br />
The motor will not maintain normal operation if the overload has<br />
not been removed because the motor contractor circuit will<br />
reopen as soon as the start button is released.<br />
The customer may incorporate a warning light or an alarm to the<br />
circuit to signal the operator of an overload or shutdown<br />
condition.<br />
Refer to Service Manual 428-440 for complete details.<br />
Overhanging Hubs<br />
When the distance between shaft ends is greater than the<br />
Coupling gap or when the coupling or clutch hub length is<br />
greater than the usable shaft length, overhang one or both hubs.<br />
For Type T41, if this results in less than one shaft diameter of hub<br />
engagement, check key stresses or use a semi-standard long T<br />
hub listed in Table 21, Page 39 or submit application details to<br />
Falk.<br />
CAUTION: The effect of open keyways on coupling or clutch<br />
balance should always be considered.<br />
Dimension Y must be equal to<br />
or greater than dimension X<br />
for clearance fits, or greater<br />
than Dimension X times .75<br />
for interference fits.<br />
X<br />
X<br />
Y<br />
Y<br />
© The Falk Corporation, 2003 (M421-110) 21