27.11.2014 Views

Multiple Limit Switches - EUCHNER GmbH + Co. KG

Multiple Limit Switches - EUCHNER GmbH + Co. KG

Multiple Limit Switches - EUCHNER GmbH + Co. KG

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Multiple</strong> <strong>Limit</strong> <strong>Switches</strong><br />

Series RGBF...AM 12 mm mechanical<br />

ff<br />

With exterior diaphragm<br />

ff<br />

Plunger spacing 12 mm<br />

ff<br />

Upright housing according to<br />

DIN 43697<br />

ff<br />

Degree of protection IP67 according to<br />

IEC 60529<br />

Series RGBF... AM mechanical<br />

Plunger spacing 12 mm<br />

Dimension drawing illustration with chisel plunger, plunger type dependent on version<br />

ø7<br />

Dog<br />

Reference surface<br />

6 ±0,1<br />

8 max.<br />

30°<br />

max.<br />

8<br />

22<br />

50<br />

6<br />

6,6<br />

40<br />

72<br />

37<br />

45<br />

70<br />

Operating point<br />

Free position<br />

Groove with sealing ring<br />

5 -1,5<br />

80<br />

100<br />

Cable entry<br />

M25 x 1.5<br />

Cable entry<br />

M25 x 1.5<br />

l 1<br />

50<br />

12<br />

30 n<br />

14<br />

50<br />

120<br />

80<br />

Exterior diaphragm<br />

The exterior diaphragm protects the plunger<br />

guide against the entry of very fine dust (dust<br />

from grinding casting, glass, etc.) and prevents<br />

the plunger seizing. At the same time, plunger<br />

sticking, caused by resinous lubricating coolants,<br />

can be prevented by this exterior diaphragm<br />

version.<br />

Switching elements<br />

ES 502 E<br />

13<br />

14<br />

21<br />

22<br />

Snap-action<br />

switching element<br />

ES 514<br />

13<br />

14<br />

21<br />

22<br />

Snap-action<br />

switching element<br />

(on request)<br />

Switching elements<br />

ff<br />

ES 502 E Snap-action switching element<br />

1 NC + 1 NO<br />

ff<br />

ES 514 Snap-action switching element<br />

1 NC +1 NO<br />

LED function display possible on request.<br />

Plunger types<br />

D<br />

Chisel<br />

Roller<br />

(plain bearing)<br />

Operating point accuracy 1) ± 0.002 ± 0.01 mm<br />

Approach speed, max. 2) 20 50 m/min<br />

1) The reproducible operating point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has<br />

been run-in with approx. 2000 operating cycles<br />

2) The approach speed specified applies in conjunction with <strong>EUCHNER</strong> trip dogs according to DIN 69639<br />

R<br />

n<br />

Number of plungers<br />

l 1<br />

2 70<br />

3 80<br />

4 90<br />

5 105<br />

6 120<br />

8 140<br />

Plunger spacing 12 mm<br />

Housing material<br />

Die-cast aluminum, anodized<br />

Plunger type Number of plungers Order No./Item<br />

2<br />

082 325<br />

RGBF 02 D 12 -502 AM -M<br />

3<br />

088 365<br />

D<br />

RGBF 03 D 12 -502 AM -M<br />

4<br />

082 326<br />

RGBF 04 D 12 -502 AM -M<br />

5<br />

088 366<br />

RGBF 05 D 12 -502 AM -M<br />

Chisel plunger<br />

6<br />

087 097<br />

RGBF 06 D 12 -502 AM -M<br />

8<br />

087 135<br />

RGBF 08 D 12 -502 AM -M<br />

2<br />

087 098<br />

RGBF 02 R 12 -502 AM -M<br />

3<br />

088 364<br />

R<br />

RGBF 03 R 12 -502 AM -M<br />

4<br />

082 327<br />

RGBF 04 R 12 -502 AM -M<br />

5<br />

087 099<br />

RGBF 05 R 12 -502 AM -M<br />

Roller plunger<br />

6<br />

087 100<br />

RGBF 06 R 12 -502 AM -M<br />

8<br />

085 730<br />

RGBF 08 R 12 -502 AM -M<br />

24<br />

Subject to technical modifications; no responsibility is accepted for the accuracy of this information.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!